AII-3000-AD Handheld O2 Analyzer
RM 0.00
SKU: AII-3000-AD
Categories: AII Analytical Industries Inc, Analytical Industries Inc, BRAND, Diving, Diving, GAS ANALYSER
Tags: AII-3000, AII-3000 and Palm O2, AII-3000-AD, AII-3000-AD Handheld O2 Analyzer, Palm CO Analyzer, Palm O2
Description
Handheld O2 Analyzer – AII-3000-AD
For Oxygen Measurement in Welding and Scuba Diving
AII-3000-AD Handheld O2 Analyzer that provides a very easy way to verify oxygen levels. For use in personnel safety, area monitoring, checking breathing air tanks, checking tanks intended for scuba diving, confirming O2 levels prior to welding.
Features
-
- 0 to 100% O2 measurement range
- Menu driven electronics
- Auto Diagnostics
- Long sensor life up to 60 months (AII-3000)(in air at 25°C and 1 atmosphere)
- Battery life up to 1,200 hours of continuous use
- Fast response time of T90 in <10 seconds
- Large backlit LCD for easy viewing
Accessories also available:
- Case and Foam Insert Polyethylene Black
- Mounting Bracket
- Sample Tubing
- Cable Coiled Handset Black 1.5 ft Retracted 12 ft Extended Telephone Jack Ends
- Cable Coiled Handset White 1.5 ft Retracted 12 ft Extended Telephone Jack Ends
AII-3000 | |||
Measurement range | 0-100% oxygen | ||
Accuracy | < ±2% of FS range under constant conditions | ||
Response time | T90 < 10 seconds | ||
Sensitivity (LDL) | 0.50% | ||
Linearity | ±1% under constant conditions | ||
Sensor model | AII-11-60 (remote sensor) AII-11-60-HC |
||
Sensor life at 25°C (77°F) and 1 atmosphere | 60 months in air 5°C (77°F) and 1 atmosphere | ||
Calibration interval | Prior to use and after 8 hours operation | ||
Inlet pressure | Ambient or 0.34-2 barg (5-30 psig) for flow through connector | ||
Flow rate (constant) | 0.2-10 Nl/min (0.4-20 SCFH) | ||
Gas connections | 1×16 mm thread 1/4″ tube for remote sensors See accessories for additional connectors |
||
Display | 3½ digit backlit LCD 7 x 3.5cm (2.75 x 1.375″); resolution 0.1 | ||
Dimensions | 9.1 x 14.9 x 4cm (3.6 x 5.9 x 1.6″) | ||
Weight | 280g (10oz) | ||
Compensation | Temperature compensated | ||
Alarms | User adjustable HI and LO alarms (AII-3000 M and MHC only) | ||
Storage temperature | -20°C to +60°C (-4°F to 140°F) on intermittent basis | ||
Operating temperature | 5 to 45°C (41°F to 113°F) | ||
Power | 2 AA alkaline batteries | ||
Battery Life | Up to 1200 hrs | ||
Humidity | Non-condensing 0-95% RH | ||
Warm up time | None | ||
Approvals | ISO 9001:2000, MDD 93/42/Annex II, ISO 13485:2003 |
Additional information
Weight | 1 kg |
---|---|
Model | AII-3000, Palm O2, Palm CO Analyzer |