STATUS FGD10 Oxygen (O2) Fixed Gas Detector
RM 0.00
SKU: FGD10 O2
Categories: BRAND, FGD10, FIXED DETECTOR, Fixed Gas Detector, Status Scientific, Status Scientific
Tags: FGD10, FGD10 Oxygen (O2) Flameproof Fixed Gas Detectors, FIXED DETECTOR, Status Scientific
Description
Flameproof Oxygen Detectors FGD10 Series Using Electrochemical Gas Sensor Technology
STATUS FGD10 Oxygen (O2) Fixed Gas Detector are used in Potentially Explosive Atmospheres. Where the nature of the environment or the industrial process taking place, there is the risk of an incendive spark from electrical apparatus causing an explosion to occur and the organisation responsible for the safety of the area requires that electrical equipment be enclosed within a flameproof enclosure
The series comprises fixed detectors with or without a window and digital display. STATUS FGD10 Oxygen (O2) Fixed Gas Detector can be supplied either in cast aluminium (standard type) or grade 316 stainless steel. The detectors are fitted with a single sensor that be either an Infrared Sensor, for the detection of Hydrocarbon gases or Carbon Dioxide, a ‘Pellistor’ Catalytic Sensor for detection of both Hydrocarbon gases and Hydrogen or an Electrochemical Sensor for the detection of specific toxic gases and oxygen.
Features
- Range 0-25% O2.
- Also available in Stainless Steel Grade 316 (as an alternative to aluminium).
- Plug-in, separately certified Ex d sensor.
- Versions available with or without a display window.
- Window version menu operates via a magnetic pen eliminating the need to open the flameproof enclosure.
- Protective weather guard can be optionally fitted.
- Can be used in conjunction with both the LC Series & MCU Series single and multi-channel control panels.
- Output – 4 to 20 mA dc (3-wire).
- 8 to 24 volt dc operation.
- Display version is fitted with 3 control relays.
- Various cable gland thread sizes available.
- Certified Ex d IIC to IECEx and ATEX.
- Approved for use in The Chinese Peoples Republic.
Versions are available for detection of the following common gas types follow the links below for further information:-
GAS TYPE |
SENSOR TECHNOLOGY |
Acetylene | Catalytic ‘Pellistor’ |
Ammonia | Electrochemical |
Carbon Dioxide | Infrared |
Carbon Monoxide | Electrochemical |
Flammable including Hydrogen | Catalytic ‘Pellistor |
Hydrogen Sulphide | Electrochemical |
Methane | Infrared |
Oxygen | Electrochemical |
Propane | Infrared |
Additional information
Weight | 2 kg |
---|