DWYER Series HM28 Handheld Digital Manometer

RM 0.00

Clear

Description

Series HM28 Handheld Digital Manometer, High Accuracy (0.2%, 0.1% or 0.05%), Differential, Gage or Absolute

 

DWYER Series HM28 Handheld Digital Manometer is designed to measure a wide range of pressures with up to 0.05% accuracy. The data logging function can store up to 964 readings and transmit the readings to a PC through an IR serial report. DWYER Series HM28 Handheld Digital Manometer dual line LCD is able to display a resolution to 0.001 of the selected unit and indicate peaks and valleys.

 

Product Applications

  • Calibration facilities
  • Laboratories

 

Features

  • Measures differential, gage, or absolute pressure
  • Able to record up to 964 readings, which can be downloaded to a PC
  • Up to 0.05% accuracy

 

Range:

Error Limit 0.2% F.S. for Gage, Under Pressure and Differential Pressure

Model Description
HM28D3B10000 Handheld digital manometer, range 0-10″ w.c.(2.5 kPa).
HM28D3C10000 Handheld digital manometer, range 0-28″ w.c. (7 kPa).
HM28D3F10000 Handheld digital manometer, range 0-120″ w.c. (30 kPa).
HM28D3H10000 Handheld digital manometer, range 0-14.5 psi (100 kPa).

 

Error Limit 0.05% F.S. for Gage, Under Pressure and Differential Pressure

Model Description
HM28D3C30000 Handheld digital manometer, range 0-28″ w.c. (7 kPa).
HM28D3F30000 Handheld digital manometer, range 0-120″ w.c. (30 kPa).
HM28D3H30000 Handheld digital manometer, range 0-14.5 psi (100 kPa).
HM28D3K30000 Handheld digital manometer, range 0-100 psi (700 kPa).
HM28D3M31000 Handheld digital manometer, range 0-245 psi (1700 kPa).

 

For Absolute Pressure

Model Description
HM28A3I10000 Handheld digital manometer, range 0-15.9 psia (0.2% F.S.) 110 kPa abs.

 

Specifications

  • Service: Air and compatible gases.
  • Accuracy: (Includes linearity, hysteresis, and repeatability): per order code. ±0.20% full scale ±1 digit. ±0.10% full scale ±1 digit. ±0.05% full scale ±1 digit.
  • Wetted Materials: 18/8 stainless steel.
  • Temperature Limits: 23 to 122°F (-5 to 50°C).
  • Storage Temperature: -4 to 140°F (-20 to 60°C).
  • Humidity: 30 to 95% rH, non-condensing.
  • Display: 2 line, 16 character, dot matrix LCD, with switchable display sizes.
  • Power Requirements: 9 V alkaline battery, installed functional, user replaceable. Can operate from external power supply of 7 to 14 VDC.
  • Current Consumption: <9 mA.
  • Memory: 964 measured values. Recording intervals adjustable from manual, 1, 5, 10, 20, 30 s, 1, 2, 3, 5, 10, 30, 60 m.
  • Case Protection: IP54 (NEMA 3).
  • Case Dimensions: 6″ x 3.27″ x 1.34″ in (152 x 83 x 34 mm).
  • Weight: 9.5 oz (270 g).
  • Pressure Connection: Hose; 4/6 mm or 1/8″ NPT.
  • Maximum Measurement Rates: Stand alone: 2-1/2 readings/sec (0.1% and 0.05% ratings), 5 readings/sec (0.2% rating). Output to RS-232: 20 measurements/sec (0.2% rating). 10 measurements/sec (0.1% and 0.05% ratings).
  • RS-232 Baud Rate: Adjustable, 1200, 2400, 4800, or 9600 baud.
  • Agency Approvals: CE.

 

 

Additional information

Weight 1 kg
Model

HM28D3B10000, HM28D3C10000, HM28D3F10000, HM28D3H10000, HM28D3C30000, HM28D3F30000, HM28D3H30000, HM28D3K30000, HM28D3M31000, HM28A3I10000