Series 610 Low Differential Pressure Transmitter
Ideal for Clean Rooms, Easy to Field Calibrate with Security Key
The Series 610 Low Differential Pressure Transmitters are capable of measuring the pressures and flow of air or non-conducting gases at high resolutions. Designed specifically for clean rooms, isolation rooms, and other critical environments, the Series 610 is ideal for situations when accurate and reliable pressure monitoring is essential. Easy access pressure ports and electrical connections, removable process heads, and detachable terminal blocks make for fast and easy installation. The Series 610 transmitters are available for air pressure ranges as low as 0.1 in w.c. full-scale. The Series 610 transmitters can be ordered as either ±0.25% or ±0.5% FS accuracy, base mount or din rail mount and the option of a digital read out display. In addition, a calibration key can be ordered that allows the user to set zero and span. One key will work on multiple transmitters.
Features
- Ranges down to 0.1″ w.c. with 0.25% or 0.5% F.S. accuracy
- Removable process head for simplified installation
- Secure operation ensured with calibration only possible via separate calibration key
- Calibration certificate included with ± 0.25% accuracy models
Specifications
- Service: Air or similar non-conducting gases.
- Accuracy: ±0.25% or ±0.5% F.S.
- Stability: ±0.5%/yr.
- Temperature Limits: -20 to 160°F (-29 to 71°C).
- Pressure Limits: 2 psi (0.137 bar).
- Thermal Effect: 0.5% FS.
- Power Requirements: 13.5 to 30 VDC.
- Output: 4 to 20 mA.
- Loop Resistance: 800 ohms max.
- Current Consumption: 25 mA.
- Zero and Span Adjustments: External security key pendant.
- Response Time: 0.02 to 0.04 seconds.
- Electrical Connections: Detachable screw terminal connector.
- Process Connections: 3/16″ O.D. barbed brass fittings on removable process head.
- Enclosure Rating: Fire retardant ABS.
- Mounting Orientation: Vertical.
- Weight: 9 oz (255 g).
- Agency Approvals: CE.
Models & Ordering
Base Mount – 0.25% Accuracy – With Display
Model | Description |
---|---|
610-01A-BDV | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-BDV | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-BDV | Low differential pressure transmitter, range ±.1″ w.c. |
610-05A-BDV | Low differential pressure transmitter, range 0 to 5″ w.c. |
610-05B-BDV | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-BDV | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-BDV | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-BDV | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-BDV | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-BDV | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-BDV | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-BDV | Low differential pressure transmitter, range 0 to .25″ w.c. |
Base Mount – 0.25% Accuracy – Without Display
Model | Description |
---|---|
610-00C-BNV | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01A-BNV | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-BNV | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-BNV | Low differential pressure transmitter, range ±.1″ w.c. |
610-05A-BNV | Low differential pressure transmitter, range 0 to 5″ w.c. |
610-05B-BNV | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-BNV | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-BNV | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-BNV | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-BNV | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-BNV | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-BNV | Low differential pressure transmitter, range ±.25″ w.c. |
Base Mount – 0.50% Accuracy – With Display
Model | Description |
---|---|
610-00C-BDE | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01A-BDE | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-BDE | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-BDE | Low differential pressure transmitter, range ±.1″ w.c. |
610-05B-BDE | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-BDE | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-BDE | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-BDE | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-BDE | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-BDE | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-BDE | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-BDE | Low differential pressure transmitter, range 0 to .25″ w.c. |
Base Mount – 0.50% Accuracy – Without Display
Model | Description |
---|---|
610-00C-BNE | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01B-BNE | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-BNE | Low differential pressure transmitter, range ±.1″ w.c. |
610-05B-BNE | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-BNE | Low differential pressure transmitter, range ±0.5″ w.c. |
610-25A-BNE | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-BNE | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-BNE | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-BNE | Low differential pressure transmitter, range 0 to .25″ w.c. |
DIN Rail Mount – 0.25% Accuracy – With Display
Model | Description |
---|---|
610-00C-DDV | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01A-DDV | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-DDV | Low differential pressure transmitter, range ± 1″ w.c. |
610-01C-DDV | Low differential pressure transmitter, range ±.1″ w.c. |
610-05A-DDV | Low differential pressure transmitter, range 0 to 5″ w.c. |
610-05B-DDV | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-DDV | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-DDV | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-DDV | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-DDV | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-DDV | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-DDV | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-DDV | Low differential pressure transmitter, range 0 to .25″ w.c. |
DIN Rail Mount – 0.25% Accuracy – Without Display
Model | Description |
---|---|
610-00C-DNV | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01A-DNV | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-DNV | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-DNV | Low differential pressure transmitter, range ±.1″ w.c. |
610-05A-DNV | Low differential pressure transmitter, range 0 to 5″ w.c. |
610-05B-DNV | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-DNV | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-DNV | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-DNV | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-DNV | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-DNV | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-DNV | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-DNV | Low differential pressure transmitter, range 0 to .25″ w.c. |
DIN Rail Mount – 0.50% Accuracy – With Display
Model | Description |
---|---|
610-00C-DDE | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01A-DDE | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-DDE | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-DDE | Low differential pressure transmitter, range ±.1″ w.c. |
610-05A-DDE | Low differential pressure transmitter, range 0 to 5″ w.c. |
610-05B-DDE | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-DDE | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-DDE | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-DDE | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-DDE | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-DDE | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-DDE | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-DDE | Low differential pressure transmitter, range 0 to .25″ w.c. |
DIN Rail Mount – 0.50% Accuracy – Without Display
Model | Description |
---|---|
610-00C-DNE | Low differential pressure transmitter, range ±0.05″ w.c. |
610-01A-DNE | Low differential pressure transmitter, range 0 to 1″ w.c. |
610-01B-DNE | Low differential pressure transmitter, range ±1″ w.c. |
610-01C-DNE | Low differential pressure transmitter, range ±.1″ w.c. |
610-05A-DNE | Low differential pressure transmitter, range 0 to 5″ w.c. |
610-05B-DNE | Low differential pressure transmitter, range ±5″ w.c. |
610-05C-DNE | Low differential pressure transmitter, range ±0.5″ w.c. |
610-05D-DNE | Low differential pressure transmitter, range 0 to .5″ w.c. |
610-10A-DNE | Low differential pressure transmitter, range 0 to 10″ w.c. |
610-25A-DNE | Low differential pressure transmitter, range 0 to 2.5″ w.c. |
610-25B-DNE | Low differential pressure transmitter, range ±2.5″ w.c. |
610-25C-DNE | Low differential pressure transmitter, range ±.25″ w.c. |
610-25D-DNE | Low differential pressure transmitter, range 0 to .25″ w.c. |
Additional information
Model | 610-01A-BDV, 610-01B-BDV, 610-01C-BDV, 610-05A-BDV, 610-05B-BDV, 610-05C-BDV, 610-05D-BDV, 610-10A-BDV, 610-25A-BDV, 610-25B-BDV, 610-25C-BDV, 610-25D-BDV, 610-00C-BNV, 610-01A-BNV, 610-01B-BNV, 610-01C-BNV, 610-05A-BNV, 610-05B-BNV, 610-05C-BNV, 610-05D-BNV, 610-10A-BNV, 610-25A-BNV, 610-25B-BNV, 610-25C-BNV, 610-00C-BDE, 610-01A-BDE, 610-01B-BDE, 610-01C-BDE, 610-05B-BDE, 610-05C-BDE, 610-05D-BDE, 610-10A-BDE, 610-25A-BDE, 610-25B-BDE, 610-25C-BDE, 610-25D-BDE, 610-00C-BNE, 610-01B-BNE, 610-01C-BNE, 610-05B-BNE, 610-05C-BNE, 610-25A-BNE, 610-25B-BNE, 610-25C-BNE, 610-25D-BNE, 610-00C-DDV, 610-01A-DDV, 610-01B-DDV, 610-01C-DDV, 610-05A-DDV, 610-05B-DDV, 610-05C-DDV, 610-05D-DDV, 610-10A-DDV, 610-25A-DDV, 610-25B-DDV, 610-25C-DDV, 610-25D-DDV, 610-00C-DNV, 610-01A-DNV, 610-01B-DNV, 610-01C-DNV, 610-05A-DNV, 610-05B-DNV, 610-05C-DNV, 610-05D-DNV, 610-10A-DNV, 610-25A-DNV, 610-25B-DNV, 610-25C-DNV, 610-25D-DNV, 610-00C-DDE, 610-01A-DDE, 610-01B-DDE, 610-01C-DDE, 610-05A-DDE, 610-05B-DDE, 610-05C-DDE, 610-05D-DDE, 610-10A-DDE, 610-25A-DDE, 610-25B-DDE, 610-25C-DDE, 610-25D-DDE, 610-00C-DNE, 610-01A-DNE, 610-01B-DNE, 610-01C-DNE, 610-05A-DNE, 610-05B-DNE, 610-05C-DNE, 610-05D-DNE, 610-10A-DNE, 610-25A-DNE, 610-25B-DNE, 610-25C-DNE, 610-25D-DNE |
---|
Related products
-
DWYER Series SYS Stainless Steel Y-Strainer
RM 0.00 Select options -
DWYER Series AT-2000 ATEX/IECEx Approved Magnehelic® Differential Pressure Gages
RM 0.00 Add to cart -
DWYER Series 2000-HA High Accuracy Magnehelic® Differential Pressure Gage
RM 0.00 Add to cart -
DWYER Series A3000 Photohelic® Pressure Switch/Gage
RM 0.00 Select options