DWYER Series 616KD-LR Pressure Transmitter
RM 0.00
SKU: 616KD-LR
Categories: BRAND, DIFFERENTIAL PRESSURE, Dwyer, Dwyer Instruments, PRESSURE TRANSMITTER, Pressure Transmitter
Tags: 616KD-LR-A34-BD1, 616KD-LR-A34-ND1, 616KD-LR-A45-BD1, 616KD-LR-A45-ND1, 616KD-LR-B31-BD1, 616KD-LR-B31-ND1, 616KD-LR-B32-BD1, 616KD-LR-B32-ND1, 616KD-LR-B34-BD1, 616KD-LR-B34-ND1, 616KD-LR-B35-BD1, 616KD-LR-B35-ND1, 616KD-LR-B41-BD1, 616KD-LR-B41-ND1, 616KD-LR-B42-BD1, 616KD-LR-B42-ND1, 616KD-LR-B45-BD1, 616KD-LR-B45-ND1, DWYER Series 616KD-LR Differential Pressure Transmitter
Description
Series 616KD-LR Differential Pressure Transmitter – Low Ranges, High Accuracy,
Ranges Down to 0.1 in w.c. (25 Pa)
The DWYER Series 616KD-LR Pressure Transmitter is designed for simplicity, making it the ideal choice for installers and maintenance professionals. DWYER Series 616KD-LR Pressure Transmitter with single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required.
Specifications
- Service: Air and non-combustible, compatible gases.
- Wetted Materials: Consult factory.
- Accuracy: ±0.25% FS for ±0.4″ (100 Pa) and ±0.5″ (125 Pa), ±0.5% FS for ±0.25″ (60 Pa), and ±1% FS for ±0.1″ (25 Pa).
- Stability: ±1% / year FSO.
- Temperature Limits: 0 to 140°F (-17.8 to 60°C).
- Pressure Limits: 1 psi max., operation; 10 psi burst.
- Power Requirements: 10 to 35 VDC (2 wire), 17 to 36 VDC or isolated 21.6 to 33 VAC (3 wire).
- Output Signal: 4 to 20 mA (2-wire), 0 to 5 VDC, 0 to 10 VDC (3-wire).
- Response Time: 2.5 Hz sample rate.
- Zero and Span Adjustments: Push buttons.
- Loop Resistance: Current Output: 0 to 1250Ω max; Voltage Output: Min. load resistance 1kΩ.
- Current Consumption: 40 mA max.
- Electrical Connections: Screw type terminal block.
- Process Connections: Barbed, dual size to fit 1/8″ & 3/16″ (3 mm & 5 mm) ID rubber or vinyl tubing, or 1/4″ NPT.
- Enclosure Rating: NEMA1 (IP20).
- Mounting Orientation: Vertical with pressure connections pointing down.
- Weight: 1.8 oz (51 g).
- Agency Approvals: CE, optional plenum rated units meet UL Standard 2043.
Models & Ordering
0.25% Accuracy
Model | Description |
---|---|
616KD-LR-A34-BD1 | Low range differential pressure transmitter, 0.4″ wc with 0.25% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-A34-ND1 | Low range differential pressure transmitter, 0.4″ wc with 0.25% accuracy, NPT process connection, front Zero push button, and dual 4-20mA & 0-10V output. |
616KD-LR-A45-BD1 | Low range differential pressure transmitter, +/- 0.5″ wc with 0.25% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-A45-ND1 | Low range differential pressure transmitter, +/- 0.5″ wc with 0.25% accuracy, NPT process connection, front Zero push button, and dual 4-20mA & 0-10V output. |
1% Accuracy
Model | Description |
---|---|
616KD-LR-B31-BD1 | Low range differential pressure transmitter, 0.1″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B31-ND1 | Low range differential pressure transmitter, 0.1″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
616KD-LR-B32-BD1 | Low range differential pressure transmitter, 0.25″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B32-ND1 | Low range differential pressure transmitter, 0.25″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
616KD-LR-B34-BD1 | Low range differential pressure transmitter, 0.4″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B34-ND1 | Low range differential pressure transmitter, 0.4″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
616KD-LR-B35-BD1 | Low range differential pressure transmitter, 0.5″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B35-ND1 | Low range differential pressure transmitter, 0.5″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
616KD-LR-B41-BD1 | Low range differential pressure transmitter, +/-0.1″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B41-ND1 | Low range differential pressure transmitter, +/-0.1″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
616KD-LR-B42-BD1 | Low range differential pressure transmitter, +/-0.25″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B42-ND1 | Low range differential pressure transmitter, +/-0.25″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
616KD-LR-B45-BD1 | Low range differential pressure transmitter, +/-0.5″ wc with 1% accuracy, barb process connection, and dual 4-20mA & 0-10V output. |
616KD-LR-B45-ND1 | Low range differential pressure transmitter, +/-0.5″ wc with 1% accuracy, NPT process connection, front Zero push button and dual 4-20mA & 0-10V output. |
Additional information
Model | 616KD-LR-A34-BD1, 616KD-LR-A34-ND1, 616KD-LR-A45-BD1, 616KD-LR-A45-ND1, 616KD-LR-B31-BD1, 616KD-LR-B31-ND1, 616KD-LR-B32-BD1, 616KD-LR-B32-ND1, 616KD-LR-B34-BD1, 616KD-LR-B34-ND1, 616KD-LR-B35-BD1, 616KD-LR-B35-ND1, 616KD-LR-B41-BD1, 616KD-LR-B41-ND1, 616KD-LR-B42-BD1, 616KD-LR-B42-ND1, 616KD-LR-B45-BD1, 616KD-LR-B45-ND1 |
---|
Related products
-
DWYER Series 3500 Differential Pressure Transmitter
RM 0.00 Select options -
DWYER Series 607D Differential Pressure Transmitter
RM 0.00 Select options -
DWYER 605 Magnehelic Differential Pressure Transmitter
RM 0.00 Select options -
DWYER Series 608 Differential Pressure Transmitter
RM 0.00 Select options