CROWCON Gas-Pro Gas Detector

RM 0.00

Description

Gas-Pro

 

CROWCON Gas-Pro Gas Detector detect gases such as hydrogen sulphide, carbon monoxide while monitoring oxygen . a portable multi-gas detector with a pre-entry check mode, providing compact detection of up to 5 gases. The Gas-Pro portable multi gas detector offers detection of up to 5 gases in a compact, reliable and intuitive solution. With simple, single button operation, it is easy to use even when wearing gloves. Its simplicity means there is minimal training time required.

With a backlit top-mount display and small size, the CROWCON Gas-Pro Gas Detector portable is a great choice for poorly lit and confined conditions. It’s also water and dust resistant and provides bump and calibration reminders, ensuring it remains reliable in even the harshest environments. An optional internal pump, activated with the flow plate, takes the pain out of pre-entry testing and allows Gas-Pro to be worn either in pumped or diffusion modes.

 

Specifications

Size 43 x 130 x 84mm (1.7 x 5.1 x 3.3ins)
Weight 309g 4 gas (10.8oz)/ 340g pumped (11.9oz)

333g 5 gas (11.7oz)/ 362g pumped (12.7oz)

Alarms Audible >95dB @ 30cm (98dB @30cm in loud mode)
Visual – all angle dual red/blue LEDs
Vibrating alert
Display Top mount for ease of view with dual colour backlight (green/red)
Data logging 125hr at 10-second intervals (45,000 logs)
Event logging Alarm, over range, calibration, bump, on/off, TWA, 1000 events
Battery Rechargeable Li-ion, >14hr (13 hours pumped operation) based on CH4, O2, H2S, CO
Typical charge time 7.5hr
Sampling Internal pump as option
Operating temperature -20°C to +55°C (-4°F to +131°F)
Storage  -20°C to +65°C (-4°F to +149°F)
Humidity 10 to 95% RH+
Ingress protection Independently tested to IP65 and IP67
Approvals IECEx: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
ATEX: II 2 G Ex db ia IIC T4 Gb Tamb -20°C to +55°C
UL: Class 1, Division 1, Groups A, B, C, and D UL 913, UL 60079-0 and UL 60079-11
INMETRO: Ex db ia IIC T4 Gb Tamb -20°C to +55°C
Marine Equipment Directive: MED 1500009
Compliance FCC and CE. Complies with EMC Directive 2014/30/EU, EN50270 and EMC FFC CFR 47 Part 15, ICES-003
Interface Data connection for gas test solutions and direct to PC
Charging Direct connection to multi-regional power supply
Vehicle charger adaptor
Desktop cradle
USB power and communications lead
Crowcon Connect Compatible? Yes

 

Gases and Ranges

Gas Range Typical Alarms Resolution
Ammonia (NH3)  0-100ppm 25ppm 1ppm
Ammonia (NH3) 0-1000ppm N/A 1ppm
Carbon Dioxide (CO2)  0-5% vol.  0-5% vol.  0.01% vol.
Carbon Monoxide (CO)  0-2000ppm  30ppm 1ppm
Carbon Monoxide (CO)  0-500ppm  30ppm 1ppm
Carbon Monoxide
(Hydrogen Filtered)
 0-2000ppm 30ppm 1ppm
Chlorine (Cl2)  0-5ppm 0.5ppm 0.1ppm
Dual toxic (CO-H2S) H2S 0-100ppm
CO 0-500ppm
5ppm
30ppm
1ppm
1ppm
Flammable  0-100% LEL  20% LEL  1% LEL
Hydrogen (H2)  0-1000ppm  N/A  1ppm
Hydrogen Sulphide (H2S)  0-100ppm  5ppm  1ppm
Nitrogen Dioxide (NO2)  0-20ppm  1ppm  0.5ppm
Oxygen (O2)  0-25% vol.  19.5% / 23.5% vol.  0.1% vol.
Ozone (O3)  0-1ppm  0.1ppm  0.01ppm
Sulphur dioxide (SO2)  0-20ppm  1ppm  0.1ppm
Chlorine dioxide (ClO2)  0-1ppm  0.1ppm  0.1ppm
Nitric oxide (NO)  0-100ppm  25ppm  1ppm

 

 

 

Additional information

Weight 1 kg