MKS BARATRON TYPE 141 VACUUM SWITCH

RM 0.00

Clear

Description

ARATRON TYPE 141 VACUUM SWITCH

 

MKS BARATRON TYPE 141 VACUUM SWITCH offers fast, accurate, and reliable protection for vacuum equipment and processes. MKS BARATRON TYPE 141 VACUUM SWITCH Designed for applications where a DC signal output is not required, the 141A has relay outputs that are easily interfaced with alarms, valve actuators, computers, process controllers, and other protection devices.

The 141 and 142 Vacuum/Pressure switches offer fast, accurate, and reliable protection for vacuum equipment and processes. Designed for applications where a Dc signal output is not required. The 141 and 142 provide relay outputs that are readily interfaced with alarms, valve actuators, computers, process controllers, or other protection devices.

 

  • Fully adjustable set point for flexibility
  • All-metal, all-welded Inconel® and stainless steel construction for corrosion resistance
  • Fast response switching – 20 msec

 

Specifications

  • Type:Pressure Switch
  • Measurement Type: Absolute
  • Full Scale Pressure Ranges: 1, 2, 10, 100, 1000 Torr (mmHg) absolute
  • Set Point Range: 0.2% to 100% of Full Scale
  • Sensor Temperature: Ambient
  • Accuracy: ±0.5% of Full Scale Range (± temperature coefficients)
  • Zero Temperature Coefficient: ±0.04% of Full Scale/°C
  • Span Temperature Coefficient: ±0.06% of set point/°C
  • Operating Temperature Range: 0° to 50°C
  • Response Time: < 20 msec from 0 to Full Scale
  • Relay Contact Ratings: DPDT, 2 amps @ 30 VDC or 1 amp @ 120 VAC resistive
  • Internal Volume: 7.0 cc (5K-25K Torr units have an 8.5 cc volume)
  • Overpressure: 120% of Full Scale or 35 psia (1000 mmHg), whichever is larger (1 and 2 Torr Full Scale units have a max. overpressure of 25 psia)
  • Power Requirements: 20 to 30 VDC, 72 mA
  • Compliance: Compliant to EMC Directive 2014/30/EU

 

Model

MODEL

FULL SCALE RANGE

FITTING TYPE

RELAY MODE

141AA-00001AA  1 Torr 0.5 in. OD tube Energizes above set point
141AA-00001AB  1 Torr 0.5 in. OD tube Energizes below set point
141AA-00001BA  1 Torr 8 VCR female Energizes above set point
141AA-00001BB  1 Torr 8 VCR female Energizes below set point
141AA-00001DA  1 Torr NW16 ISO-KF Energizes above set point
141AA-00001DB  1 Torr NW16 ISO-KF Energizes below set point
141AA-00010AA
10 Torr 0.5 in. OD tube Energizes above set point
141AA-00010AB  10 Torr 0.5 in. OD tube Energizes below set point
141AA-00010BA  10 Torr 8 VCR female Energizes above set point
141AA-00010BB  10 Torr 8 VCR female Energizes below set point
141AA-00010DA  10 Torr NW16 ISO-KF Energizes above set point
141AA-00010DB  10 Torr NW16 ISO-KF Energizes below set point
141AA-00100AA  100 Torr 0.5 in. OD tube Energizes above set point
141AA-00100AB  100 Torr 0.5 in. OD tube Energizes below set point
141AA-00100BA  100 Torr 8 VCR female Energizes above set point
141AA-00100BB  100 Torr 8 VCR female Energizes below set point
141AA-00100DA  100 Torr NW16 ISO-KF Energizes above set point
141AA-00100DB  1000 Torr NW16 ISO-KF Energizes below set point
141AA-01000AA  1000 Torr 0.5 in. OD tube Energizes above set point
141AA-01000AB  1000 Torr 0.5 in. OD tube Energizes below set point
141AA-01000BA  1000 Torr 8 VCR female Energizes above set point
141AA-01000BB  1000 Torr 8 VCR female Energizes below set point
141AA-01000DA  1000 Torr NW16 ISO-KF Energizes above set point
141AA-01000DB  1000 Torr NW16 ISO-KF Energizes below set point

 

 

Additional information

Weight 0.3 kg
Model

141AA-00001AA, 141AA-00001AB, 141AA-00001BA, 141AA-00001BB, 141AA-00001DA, 141AA-00001DB, 141AA-00010AA, 141AA-00010AB, 141AA-00010BA, 141AA-00010BB, 141AA-00010DA, 141AA-00010DB, 141AA-00100AA, 141AA-00100AB, 141AA-00100BA, 141AA-00100BB, 141AA-00100DA, 141AA-00100DB, 141AA-01000AA, 141AA-01000AB, 141AA-01000BA, 141AA-01000BB, 141AA-01000DA, 141AA-01000DB