DWYER Series CXA Water Pump Pressure Switch

RM 0.00

Clear

Description

Series CXA Water Pump Pressure Switch, Simple, Reliable, Adjustable Set Point and

Deadband

 

DWYER Series CXA Water Pump Pressure Switch have been proven reliable for controlling automatic water systems. These switches are very popular for use on water well pumps and pumping systems. The set point and deadband are both easily adjustable via screws inside the cover. For ease of installation, the switches come with a 1/4″ female NPT process connection and can be mounted in any orientation. DWYER Series CXA Water Pump Pressure Switch simple design makes it a great switch for an installer at any skill level.

Product Applications

  • Water system applications
  • Electric water pumps
  • Well pumps
  • Pumping systems

 

Features

  • The set point and deadband are both easily adjustable reducing time to install and operation
  • Mounting in any position and feature simple makes a reliable switch that can be installed by any skill level

 

Specifications

  • Service: Compatible liquids and gases.
  • Wetted Materials: Silicone, steel, and SS.
  • Temperature Limits: 140°F (60°C).
  • Pressure Limits: See model chart on catalog page.
  • Enclosure Rating: General purpose.
  • Repeatability: ±5 psig (±0.3 bar).
  • Switch Type: DPST snap action (see model chart on catalog page).
  • Electrical Ratings: 20 A @ 120 VAC, 12 A @ 240 VAC, 9.6 A @ 240 VAC (3 phase), 8.6 A @ 32 VDC, 3.1 A @ 120 VDC, 1.6 A @ 240 VDC.
  • Electrical Connections: Screw terminal.
  • Conduit Connection: 7/8″ hole for 1/2″ conduit hub (2 places).
  • Process Connection: 1/4″ female NPT.
  • Mounting Orientation: Switch can be installed in any position.
  • Set Point Adjustment: Internal screws.
  • Deadband: See model chart on Catalog Page.
  • Weight: 0.75 lb (0.34 kg).
  • Agency Approvals: CE.

 

Models & Ordering

Model Description
CXA-R1 Water pump pressure switch, NO, range 15-80 psig (1.0-5.5 bar), approx. adj. deadband 15-30 psig (1.0-2.1 bar), max. pressure 129 psig (8.9 bar).
CXA-R2 Water pump pressure switch, NO, range 30-100 psig (2.1-6.9 bar), approx. adj. deadband 20-35 psig (1.4-2.4 bar), max. pressure 179 psig (12.3 bar).
CXA-R3 Water pump pressure switch, NO, range 35-150 psig (2.4-10.3 bar), approx. adj. deadband 30-40 psig (2.1-2.8 bar), max. pressure 204 psig (14.1 bar).
CXA-S1 Water pump pressure switch, NC, range 15-80 psig (1.0-5.5 bar), approx. adj. deadband 15-30 psig (1.0-2.1 bar), max. pressure 129 psig (8.9 bar).
CXA-S2 Water pump pressure switch, NC, range 30-100 psig (2.1-6.9 bar), approx. adj. deadband 20-35 psig (1.4-2.4 bar), max. pressure 179 psig (12.3 bar).
CXA-S3 Water pump pressure switch, NC, range 35-150 psig (2.4-10.3 bar), approx. adj. deadband 30-40 psig (2.1-2.8 bar), max. pressure 204 psig (14.1 bar).

 

 

 

 

 

 

 

 

Additional information

Model

CXA-R1, CXA-R2, CXA-R3, CXA-S1, CXA-S2, CXA-S3