DWYER Series A3000 Photohelic Pressure Switch/Gage function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magnehelic® gage design. DWYER Series A3000 Photohelic Pressure Switch/Gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust set point indicators are controlled by knobs located on the gage face.
Specifications
GAGE SPECIFICATIONS
- Service: Air and non-combustible, compatible gases.
- Wetted Materials: Consult Factory.
- Accuracy: ±2% of FS at 70°F (21.1°C). ±3% on -0 and ±4% on -00 models.
- Pressure Limits: -20″ Hg. to 25 psig (-0.677 to 1.72 bar). MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar).
- Temperature Limits: 20 to 120°F. (-6.67 to 48.9°C). -20 to 120°F (-28 to 48.9°C) with low temperature option.
- Process Connections: 1/8″ female NPT.
- Size: 4″ (101.6 mm) dial face, 5″ (127 mm) O.D. x 8-1/4″ (209.55 mm).
- Weight: 4 lb (1.81 kg).
SWITCH SPECIFICATIONS
- Switch Type: Each setpoint has 2 Form C relays (DPDT).
- Repeatability: ±1% of FS .
- Electrical Rating: 10 A @ 28 VDC, 10 A @ 120, 240 VAC.
- Electrical Connections: Screw terminals. Use 167°F (75°C) copper conductors only.
- Power Requirements: 120 VAC, 50/60 Hz; 240 VAC & 24 VAC power optional.
- Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
- Set Point Adjustment: Adjustable knobs on face.
- Agency Approvals: CE, CSA, UL.
Features
- Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic® switch/gage set point mechanism. Cover is clear polycarbonate plastic.
- Gage pointer and light shutter are mounted on helix and balancing counterweight. Shutter passes through slot in optical limit switch to expose phototransistors to integral infrared light source or mask them depending on applied pressure.
- Light shield effectively protects phototransistors from strong outside light sources yet allows free pointer movement. It also gives interior a clean “finished” look.
- Optical limit switches are used for reliability and long service life. Attached directly to set pointers, they are individually aligned to assure precise switching accuracy.
- Semi-Flexible drive shaft connects to set point knobs.
- Zero adjustment screw connects to screw in cover to adjust zero pressure reading.
- Plastic enclosure protects electronic components and electrical connections.
- Polycarbonate connection or terminal board is self-extinguishing.
- Glass epoxy printed circuit boards for durability and permanence.
- Load relays are DPDT with latching feature for maximum application versatility.
- Electronics are designed to operate on 50/60 Hz, 120 volt current with 10% over or under voltage. Special units for other voltages are available.
- Switch set pointers show switch settings at all times.
- Spring loaded friction clutch prevents operator damage of set point mechanism.
- 3-in-1 instrument allows the reduction of several instruments with one product, saving inventory, installation time and money.
- Patented design and 1% full scale dead band provides quick response to pressure changes means no delay in switching and chatter-free operation.
- A wide range of models that can meet pressure measurement specifications from low to very high.
Models & Ordering
Inches of w.c.
Model | Description |
---|---|
A3000-0 | Pressure switch/gage, range 0-.50″ w.c. |
A3000-00 | Pressure switch/gage, range 0-.25″ w.c. |
A3001 | Pressure switch/gage, range 0-1.0″ w.c. |
A3002 | Pressure switch/gage, range 0-2.0″ w.c. |
A3003 | Pressure switch/gage, range 0-3.0″ w.c. |
A3004 | Pressure switch/gage, range 0-4.0″ w.c. |
A3005 | Pressure switch/gage, range 0-5.0″ w.c. |
A3006 | Pressure switch/gage, range 0-6.0″ w.c. |
A3008 | Pressure switch/gage, range 0-8.0″ w.c. |
A3010 | Pressure switch/gage, range 0-10″ w.c. |
A3015 | Pressure switch/gage, range 0-15″ w.c. |
A3020 | Pressure switch/gage, range 0-20″ w.c. |
A3025 | Pressure switch/gage, range 0-25″ w.c. |
A3030 | Pressure switch/gage, range 0-30″ w.c. |
A3040 | Pressure switch/gage, range 0-40″ w.c. |
A3050 | Pressure switch/gage, range 0-50″ w.c. |
A3060 | Pressure switch/gage, range 0-60″ w.c. |
A3080 | Pressure switch/gage, range 0-80″ w.c. |
A3100 | Pressure switch/gage, range 0-100″ w.c. |
A3150 | Pressure switch/gage, range 0-150″ w.c. |
Inches of w.c. – Zero Center
Model | Description |
---|---|
A3300-0 | Pressure switch/gage, range .25-0-.25″ w.c. |
A3301 | Pressure switch/gage, range .5-0-.5″ w.c. |
A3302 | Pressure switch/gage, range 1-0-1″ w.c. |
A3304 | Pressure switch/gage, range 2-0-2″ w.c. |
A3310 | Pressure switch/gage, range 5-0-5″ w.c. |
A3320 | Pressure switch/gage, range 10-0-10″ w.c. |
A3330 | Pressure switch/gage, range 15-0-15″ w.c. |
PSI
Model | Description |
---|---|
A3201 | Pressure switch/gage, range 0-1 psi. |
A3202 | Pressure switch/gage, range 0-2 psi. |
A3203 | Pressure switch/gage, range 0-3 psi. |
A3204 | Pressure switch/gage, range 0-4 psi. |
A3205 | Pressure switch/gage, range 0-5 psi. |
A3210 | Pressure switch/gage, range 0-10 psi, medium pressure option standard. |
A3215 | Pressure switch/gage, range 0-15 psi, medium pressure option standard. |
A3220 | Pressure switch/gage, range 0-20 psi, medium pressure option standard. |
A3230 | Pressure switch/gage, range 0-30 psi, high pressure option standard. |
Inches of w.c./Air Velocity FPM
Model | Description |
---|---|
A3000-00AV | Pressure switch/gage, range 0-.25″ w.c./300-2000 FPM. Note: Pitot tube required. |
A3000-0AV | Pressure switch/gage, range 0-.50″ w.c./500-2800 FPM. Note: Pitot tube required. |
A3001AV | Pressure switch/gage, range 0-1.0″ w.c.500-4000 FPM. Note: Pitot tube required. |
A3002AV | Pressure switch/gage, range 0-2.0″ w.c./1000-5600 FPM. Note: Pitot tube required. |
A3010AV | Pressure switch/gage, range 0-10″ w.c./2000-12500 FPM. Note: Pitot tube required. |
MM of w.c.
Model | Description |
---|---|
A3000-100MM | Pressure switch/gage, range 0-100 mm w.c. |
A3000-10MM | Pressure switch/gage, range 0-10 mm w.c. |
A3000-25MM | Pressure switch/gage, range 0-25 mm w.c. |
A3000-50MM | Pressure switch/gage, range 0-50 mm w.c. |
A3000-6MM | Pressure switch/gage, range 0-6 mm w.c. |
A3000-80MM | Pressure switch/gage, range 0-80 mm w.c. |
MM of w.c. – Zero Center
Model | Description |
---|---|
A3300-20MM | Pressure switch/gage, range 10-0-10 mm w.c. |
A3300-30MM | Pressure switch/gage, range 15-0-15 mm w.c. |
CM of w.c.
Model | Description |
---|---|
A3000-100CM | Pressure switch/gage, range 0-100 cm w.c. |
A3000-150CM | Pressure switch/gage, range 0-150 cm w.c. |
A3000-15CM | Pressure switch/gage, range 0-15 cm w.c. |
A3000-200CM | Pressure switch/gage, range 0-200 cm w.c. |
A3000-20CM | Pressure switch/gage, range 0-20 cm w.c. |
A3000-250CM | Pressure switch/gage, range 0-250 cm w.c. |
A3000-25CM | Pressure switch/gage, range 0-25 cm w.c. |
A3000-300CM | Pressure switch/gage, range 0-300 cm w.c. |
A3000-50CM | Pressure switch/gage, range 0-50 cm w.c. |
A3000-80CM | Pressure switch/gage, range 0-80 cm w.c. |
Pascals
Model | Description |
---|---|
A3000-125PA | Pressure switch/gage, range 0-125 Pa. |
A3000-250PA | Pressure switch/gage, range 0-250 Pa. |
A3000-500PA | Pressure switch/gage, range 0-500 Pa. |
A3000-60PA | Pressure switch/gage, range 0-60 Pa. |
A3000-750PA | Pressure switch/gage, range 0-750 Pa. |
Pascals – Zero Center
Model | Description |
---|---|
A3300-250PA | Pressure switch/gage, range 125-0-125 Pa. |
A3300-500PA | Pressure switch/gage, range 250-0-250 Pa. |
Kilopascals
Model | Description |
---|---|
A3000-1.5KPA | Pressure switch/gage, range 0-1.5 kPa. |
A3000-10KPA | Pressure switch/gage, range 0-10 kPa. |
A3000-15KPA | Pressure switch/gage, range 0-15 kPa. |
A3000-1KPA | Pressure switch/gage, range 0-1 kPa. |
A3000-20KPA | Pressure switch/gage, range 0-20 kPa. |
A3000-25KPA | Pressure switch/gage, range 0-25 kPa. |
A3000-30KPA | Pressure switch/gage, range 0-30 kPa. |
A3000-3KPA | Pressure switch/gage, range 0-3 kPa. |
A3000-4KPA | Pressure switch/gage, range 0-4 kPa. |
A3000-5KPA | Pressure switch/gage, range 0-5 kPa. |
A3000-8KPA | Pressure switch/gage, range 0-8 kPa. |
Kilopascals – Zero Center
Model | Description |
---|---|
A3300-1KPA | Pressure switch/gage, range .5-0-.5 kPa. |
A3300-3KPA | Pressure switch/gage, range 1.5-0-1.5 kPa. |
Bi-Directional
Model | Description |
---|---|
A3000-00N | Pressure switch/gage, range .05 to .20″ w.c. |
Additional information
Model | A3000-0, A3000-00, A3001, A3002, A3003, A3004, A3005, A3006, A3008, A3010, A3015, A3020, A3025, A3030, A3040, A3050, A3060, A3080, A3100, A3150, A3300-0, A3301, A3302, A3304, A3310, A3320, A3330, A3201, A3202, A3203, A3204, A3205, A3210, A3215, A3220, A3230, A3000-00AV, A3000-0AV, A3001AV, A3002AV, A3010AV, A3000-100MM, A3000-10MM, A3000-25MM, A3000-50MM, A3000-6MM, A3000-80MM, A3300-20MM, A3300-30MM, A3000-100CM, A3000-150CM, A3000-15CM, A3000-200CM, A3000-20CM, A3000-250CM, A3000-25CM, A3000-300CM, A3000-50CM, A3000-80CM, A3000-125PA, A3000-250PA, A3000-500PA, A3000-60PA, A3000-750PA, A3300-250PA, A3300-500PA, A3000-1.5KPA, A3000-10KPA, A3000-15KPA, A3000-1KPA, A3000-20KPA, A3000-25KPA, A3000-30KPA, A3000-3KPA, A3000-4KPA, A3000-5KPA, A3000-8KPA, A3300-1KPA, A3300-3KPA, A3000-00N |
---|