DWYER Series 668 Differential Pressure Transmitter
RM 0.00
Description
Series 668 Differential Pressure Transmitter, Ranges from 0 to 100″ w.c., Overpressure
Protection to 10 psig, ±1% Accuracy
DWYER Series 668 Differential Pressure Transmitter is capable of measuring low pressures with a ±1% accuracy – ideally suited for proper building pressurization and air flow control. Transmitters can withstand up to 10 psig overpressure with no damage to the unit. Variable capacitance sensor design provides excellent sensitivity and long-term stability. DWYER Series 668 Differential Pressure Transmitter is compact, lightweight design makes installation simple and easy. Units also feature reverse-polarity protection.
Features
- Good accuracy at low pressure ranges provides exceptional value for ensuring control and minimizing costly out of specification conditions
- High overpressure rating eliminates possible damage to unit reducing unnecessary service time
Specifications
- Service: Air and non-conductive gases.
- Accuracy: ±1% FS (RSS), (includes non-linearity, hysteresis, and non-repeatability).
- Temperature Limits: Operating: 0 to 150°F (-18 to 65°C), Storage: -40 to 185°F (-40 to 85°C).
- Pressure Limits: 10 psig (0.69 bar).
- Compensated Temperature Range: 0 to 150°F (-18 to 65°C).
- Thermal Effects: 0.033% FS/°F (0.18% FS/°C).
- Supply Voltage: 12 to 30 VDC.
- Output: 4 to 20 mA, 2-wire.
- Zero and Span Adjustment: ±1 mA, non-interactive.
- Response Time: <60 msec.
- Loop Resistance: 0 to 800 Ω.
- Electrical Connection: Terminal strip.
- Pressure Connection: 3/16″ OD fitting for 1/4″ ID tubing.
- Housing: Fire retardant glass filled polyester.
- Weight: 3 oz (85 g).
- Agency Approval: CE.
Models & Ordering
Standard Ranges
Model | Description |
---|---|
668-1 | Differential pressure transmitter, range 0-0.25″ w.c. |
668-19 | Differential pressure transmitter, range 0-0.4″ w.c. |
668-2 | Differential pressure transmitter, range 0-0.5″ w.c. |
668-3 | Differential pressure transmitter, range 0-1.0″ w.c. |
668-4 | Differential pressure transmitter, range 0-2.5″ w.c. |
668-5 | Differential pressure transmitter, range 0-5.0″ w.c. |
668-6 | Differential pressure transmitter, range 0-10″ w.c. |
668-7 | Differential pressure transmitter, range 0-25″ w.c. |
668-8 | Differential pressure transmitter, range 0-50″ w.c. |
668-9 | Differential pressure transmitter, range 0-100″ w.c. |
Bi-Directional Ranges
Model | Description |
---|---|
668-10 | Differential pressure transmitter, bi-directional, range 0 to ±0.1″ w.c. |
668-11 | Differential pressure transmitter, bi-directional, range 0 to ±0.25″ w.c. |
668-12 | Differential pressure transmitter, bi-directional, range 0 to ±0.5″ w.c. |
668-13 | Differential pressure transmitter, bi-directional, range 0 to ±1″ w.c. |
668-14 | Differential pressure transmitter, bi-directional, range 0 to ±2.5″ w.c. |
668-15 | Differential pressure transmitter, bi-directional, range 0 to ±5″ w.c. |
668-16 | Differential pressure transmitter, bi-directional, range 0 to ±10″ w.c. |
668-17 | Differential pressure transmitter, bi-directional, range 0 to ±25″ w.c. |
668-18 | Differential pressure transmitter, bi-directional, range 0 to ±50″ w.c. |
668-20 | Differential pressure transmitter, bi-directional, range -0.05 to .20″ w.c |
Standard Ranges with Conduit Cover
Model | Description |
---|---|
668C-1 | Differential pressure transmitter with conduit cover, range 0-0.25″ w.c. |
668C-2 | Differential pressure transmitter with conduit cover, range 0-0.5″ w.c. |
668C-3 | Differential pressure transmitter with conduit cover, range 0-1.0″ w.c. |
668C-4 | Differential pressure transmitter with conduit cover, range 0-2.5″ w.c. |
668C-5 | Differential pressure transmitter with conduit cover, range 0-5.0″ w.c. |
668C-6 | Differential pressure transmitter with conduit cover, range 0-10″ w.c. |
668C-7 | Differential pressure transmitter with conduit cover, range 0-25″ w.c. |
668C-8 | Differential pressure transmitter with conduit cover, range 0-50″ w.c. |
668C-9 | Differential pressure transmitter with conduit cover, range 0-100″ w.c. |
Bi-Directional Ranges with Conduit Cover
Model | Description |
---|---|
668C-10 | Differential pressure transmitter with conduit cover, range 0 to ±0.1″ w.c. |
668C-11 | Differential pressure transmitter with conduit cover, range 0 to ±0.25″ w.c. |
668C-12 | Differential pressure transmitter with conduit cover, range 0 to ±0.5″ w.c. |
668C-13 | Differential pressure transmitter with conduit cover, range 0 to ±1″ w.c. |
668C-14 | Differential pressure transmitter with conduit cover, range 0 to ±2.5″ w.c. |
668C-15 | Differential pressure transmitter with conduit cover, range 0 to ±5″ w.c. |
668C-16 | Differential pressure transmitter with conduit cover, range 0 to ±10″ w.c. |
668C-17 | Differential pressure transmitter with conduit cover, range 0 to ±25″ w.c. |
668C-18 | Differential pressure transmitter with conduit cover, range 0 to ±50″ w.c. |
668C-19 | Differential pressure transmitter with conduit housing, range 0 to 0.4″ w.c. |
Additional information
Model | 668-1, 668-19, 668-2, 668-3, 668-4, 668-5, 668-6, 668-7, 668-8, 668-9, 668-10, 668-11, 668-12, 668-13, 668-14, 668-15, 668-16, 668-17, 668-18, 668-20, 668C-1, 668C-2, 668C-3, 668C-4, 668C-5, 668C-6, 668C-7, 668C-8, 668C-9, 668C-10, 668C-11, 668C-12, 668C-13, 668C-14, 668C-15, 668C-16, 668C-17, 668C-18, 668C-19 |
---|