Series 610 Low Differential Pressure Transmitter, Ideal for Clean Rooms, Easy to Field

Calibrate with Security Key

 

The DWYER Series 610 Differential Pressure Transmitter are capable of measuring the pressures and flow of air or non-conducting gases at high resolutions. Designed specifically for clean rooms, isolation rooms, and other critical environments, the DWYER Series 610 Differential Pressure Transmitter is ideal for situations when accurate and reliable pressure monitoring is essential. Easy access pressure ports and electrical connections, removable process heads, and detachable terminal blocks make for fast and easy installation.

 

Features

  • Ranges down to 0.1″ w.c. with 0.25% or 0.5% F.S. accuracy
  • Removable process head for simplified installation
  • Secure operation ensured with calibration only possible via separate calibration key
  • Calibration certificate included with ± 0.25% accuracy models

 

Specifications

  • Service: Air or similar non-conducting gases.
  • Accuracy: ±0.25% or ±0.5% F.S.
  • Stability: ±0.5%/yr.
  • Temperature Limits: -20 to 160°F (-29 to 71°C).
  • Pressure Limits: 2 psi (0.137 bar).
  • Thermal Effect: 0.5% FS.
  • Power Requirements: 13.5 to 30 VDC.
  • Output: 4 to 20 mA.
  • Loop Resistance: 800 ohms max.
  • Current Consumption: 25 mA.
  • Zero and Span Adjustments: External security key pendant.
  • Response Time: 0.02 to 0.04 seconds.
  • Electrical Connections: Detachable screw terminal connector.
  • Process Connections: 3/16″ O.D. barbed brass fittings on removable process head.
  • Enclosure Rating: Fire retardant ABS.
  • Mounting Orientation: Vertical.
  • Weight: 9 oz (255 g).
  • Agency Approvals: CE.

 

Models & Ordering

 

Base Mount – 0.25% Accuracy – With Display

Model Description
610-01A-BDV Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-BDV Low differential pressure transmitter, range ±1″ w.c.
610-01C-BDV Low differential pressure transmitter, range ±.1″ w.c.
610-05A-BDV Low differential pressure transmitter, range 0 to 5″ w.c.
610-05B-BDV Low differential pressure transmitter, range ±5″ w.c.
610-05C-BDV Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-BDV Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-BDV Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-BDV Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-BDV Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-BDV Low differential pressure transmitter, range ±.25″ w.c.
610-25D-BDV Low differential pressure transmitter, range 0 to .25″ w.c.

 

Base Mount – 0.25% Accuracy – Without Display

Model Description
610-00C-BNV Low differential pressure transmitter, range ±0.05″ w.c.
610-01A-BNV Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-BNV Low differential pressure transmitter, range ±1″ w.c.
610-01C-BNV Low differential pressure transmitter, range ±.1″ w.c.
610-05A-BNV Low differential pressure transmitter, range 0 to 5″ w.c.
610-05B-BNV Low differential pressure transmitter, range ±5″ w.c.
610-05C-BNV Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-BNV Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-BNV Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-BNV Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-BNV Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-BNV Low differential pressure transmitter, range ±.25″ w.c.

 

Base Mount – 0.50% Accuracy – With Display

Model Description
610-00C-BDE Low differential pressure transmitter, range ±0.05″ w.c.
610-01A-BDE Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-BDE Low differential pressure transmitter, range ±1″ w.c.
610-01C-BDE Low differential pressure transmitter, range ±.1″ w.c.
610-05B-BDE Low differential pressure transmitter, range ±5″ w.c.
610-05C-BDE Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-BDE Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-BDE Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-BDE Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-BDE Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-BDE Low differential pressure transmitter, range ±.25″ w.c.
610-25D-BDE Low differential pressure transmitter, range 0 to .25″ w.c.

 

Base Mount – 0.50% Accuracy – Without Display

Model Description
610-00C-BNE Low differential pressure transmitter, range ±0.05″ w.c.
610-01B-BNE Low differential pressure transmitter, range ±1″ w.c.
610-01C-BNE Low differential pressure transmitter, range ±.1″ w.c.
610-05B-BNE Low differential pressure transmitter, range ±5″ w.c.
610-05C-BNE Low differential pressure transmitter, range ±0.5″ w.c.
610-25A-BNE Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-BNE Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-BNE Low differential pressure transmitter, range ±.25″ w.c.
610-25D-BNE Low differential pressure transmitter, range 0 to .25″ w.c.

 

DIN Rail Mount – 0.25% Accuracy – With Display

Model Description
610-00C-DDV Low differential pressure transmitter, range ±0.05″ w.c.
610-01A-DDV Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-DDV Low differential pressure transmitter, range ± 1″ w.c.
610-01C-DDV Low differential pressure transmitter, range ±.1″ w.c.
610-05A-DDV Low differential pressure transmitter, range 0 to 5″ w.c.
610-05B-DDV Low differential pressure transmitter, range ±5″ w.c.
610-05C-DDV Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-DDV Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-DDV Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-DDV Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-DDV Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-DDV Low differential pressure transmitter, range ±.25″ w.c.
610-25D-DDV Low differential pressure transmitter, range 0 to .25″ w.c.

 

DIN Rail Mount – 0.25% Accuracy – Without Display

Model Description
610-00C-DNV Low differential pressure transmitter, range ±0.05″ w.c.
610-01A-DNV Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-DNV Low differential pressure transmitter, range ±1″ w.c.
610-01C-DNV Low differential pressure transmitter, range ±.1″ w.c.
610-05A-DNV Low differential pressure transmitter, range 0 to 5″ w.c.
610-05B-DNV Low differential pressure transmitter, range ±5″ w.c.
610-05C-DNV Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-DNV Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-DNV Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-DNV Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-DNV Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-DNV Low differential pressure transmitter, range ±.25″ w.c.
610-25D-DNV Low differential pressure transmitter, range 0 to .25″ w.c.

 

DIN Rail Mount – 0.50% Accuracy – With Display

Model Description
610-00C-DDE Low differential pressure transmitter, range ±0.05″ w.c.
610-01A-DDE Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-DDE Low differential pressure transmitter, range ±1″ w.c.
610-01C-DDE Low differential pressure transmitter, range ±.1″ w.c.
610-05A-DDE Low differential pressure transmitter, range 0 to 5″ w.c.
610-05B-DDE Low differential pressure transmitter, range ±5″ w.c.
610-05C-DDE Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-DDE Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-DDE Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-DDE Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-DDE Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-DDE Low differential pressure transmitter, range ±.25″ w.c.
610-25D-DDE Low differential pressure transmitter, range 0 to .25″ w.c.

 

DIN Rail Mount – 0.50% Accuracy – Without Display

Model Description
610-00C-DNE Low differential pressure transmitter, range ±0.05″ w.c.
610-01A-DNE Low differential pressure transmitter, range 0 to 1″ w.c.
610-01B-DNE Low differential pressure transmitter, range ±1″ w.c.
610-01C-DNE Low differential pressure transmitter, range ±.1″ w.c.
610-05A-DNE Low differential pressure transmitter, range 0 to 5″ w.c.
610-05B-DNE Low differential pressure transmitter, range ±5″ w.c.
610-05C-DNE Low differential pressure transmitter, range ±0.5″ w.c.
610-05D-DNE Low differential pressure transmitter, range 0 to .5″ w.c.
610-10A-DNE Low differential pressure transmitter, range 0 to 10″ w.c.
610-25A-DNE Low differential pressure transmitter, range 0 to 2.5″ w.c.
610-25B-DNE Low differential pressure transmitter, range ±2.5″ w.c.
610-25C-DNE Low differential pressure transmitter, range ±.25″ w.c.
610-25D-DNE Low differential pressure transmitter, range 0 to .25″ w.c.

 

 

 

 

 

Additional information

Model

610-01A-BDV, 610-01B-BDV, 610-01C-BDV, 610-05A-BDV, 610-05B-BDV, 610-05C-BDV, 610-05D-BDV, 610-10A-BDV, 610-25A-BDV, 610-25B-BDV, 610-25C-BDV, 610-25D-BDV, 610-00C-BNV, 610-01A-BNV, 610-01B-BNV, 610-01C-BNV, 610-05A-BNV, 610-05B-BNV, 610-05C-BNV, 610-05D-BNV, 610-10A-BNV, 610-25A-BNV, 610-25B-BNV, 610-25C-BNV, 610-00C-BDE, 610-01A-BDE, 610-01B-BDE, 610-01C-BDE, 610-05B-BDE, 610-05C-BDE, 610-05D-BDE, 610-10A-BDE, 610-25A-BDE, 610-25B-BDE, 610-25C-BDE, 610-25D-BDE, 610-00C-BNE, 610-01B-BNE, 610-01C-BNE, 610-05B-BNE, 610-05C-BNE, 610-25A-BNE, 610-25B-BNE, 610-25C-BNE, 610-25D-BNE, 610-00C-DDV, 610-01A-DDV, 610-01B-DDV, 610-01C-DDV, 610-05A-DDV, 610-05B-DDV, 610-05C-DDV, 610-05D-DDV, 610-10A-DDV, 610-25A-DDV, 610-25B-DDV, 610-25C-DDV, 610-25D-DDV, 610-00C-DNV, 610-01A-DNV, 610-01B-DNV, 610-01C-DNV, 610-05A-DNV, 610-05B-DNV, 610-05C-DNV, 610-05D-DNV, 610-10A-DNV, 610-25A-DNV, 610-25B-DNV, 610-25C-DNV, 610-25D-DNV, 610-00C-DDE, 610-01A-DDE, 610-01B-DDE, 610-01C-DDE, 610-05A-DDE, 610-05B-DDE, 610-05C-DDE, 610-05D-DDE, 610-10A-DDE, 610-25A-DDE, 610-25B-DDE, 610-25C-DDE, 610-25D-DDE, 610-00C-DNE, 610-01A-DNE, 610-01B-DNE, 610-01C-DNE, 610-05A-DNE, 610-05B-DNE, 610-05C-DNE, 610-05D-DNE, 610-10A-DNE, 610-25A-DNE, 610-25B-DNE, 610-25C-DNE, 610-25D-DNE