CROWCON IRmax Fixed Point Gas Detector

RM 0.00

Description

IRmax

CROWCON IRmax Fixed Point Gas Detector is a compact, low power and highly rugged infrared (IR) gas detector.  CROWCON IRmax Fixed Point Gas Detector delivers rapid, fail-safe detection of many gas  and other hydrocarbon gases and vapours. The remote display can be mounted up to 30 metres from the IRmax and test gas can be applied without requiring direct access to the detector.

Specifications

IRmax with Fixed IR display with IS Barrier Module Remote IR Display
Size 158 x 75 x 57mm (6.2 x 2.9 x 2.3ins) 230 x 75 x 57mm (9 x 2.9 x 2.3ins) 261 x 75 x 57mm (2.3 x 2.9 x 2.3ins) 60 x 54 x 48mm (2.3 x 2.1 x 1.9ins)
Weight 1.58kg (3.5lbs) 2kg (4.4lbs) 2.4kg (5.3lbs) 0.2kg (0.4lbs)
Ingress protection IP66
Enclosure material 316 stainless steel
Power 12-30 Vdc. < 1W
Connection One M20 or 1/2” NPT cable gland entry
Electrical output 4-20mA current sink or source
2mA dirty optics warning (at 75% obscuration, configurable)
0mA detector fault signal (at 90% obscuration, configurable)
RS-485 Modbus (optional), HART 7 (optional)
Operating temperature -40°C to +75°C (-40°F to 167°F)
Humidity 0 to 95% RH non-condensing
Pressure range Atmospheric +/- 10%
Repeatability +/- 2% FSD
Zero drift +/- 2% FSD per year maximum
Response time T-90 <4 seconds
Functional safety Validation to IEC61508, EN50402 SIL 2
Approvals Ex II 2 GD
Exd IIC T6 Gb (Tamb -40to+50°C),
T4 (Tamb -40to+75°C)
Ex tb IIIC T135°C Db (Tamb -40 to +75°C)
Ex II 2 G
Exd ia IIC T4 Gb (Tamb -40to+75°C)
Ex II 2 GD
Exd ia IIC T4 Gb (Tamb -40to+75°C)
Ex tb IIIC T135°C Db (Tamb -40 to +40°C)
EMC compliance Directive 2014/30 EU: EN50270, FCC CFR47 Part 15B, ICES-003
Zones Certified for use in Zone 1 & 2.

 

Additional information

Weight 1 kg