CITY CiTiceL sensor replacement

RM 0.00

Description

CiTiceL 4OXV Replacement Oxygen Sensor compatible with following BW Technologies models: BW Technologies GasAlert MicroClip XT BW Technologies GasAlert Max XT-II BW Technologies GasAlert Micro BW Technologies GasAlert Micro 5 BW Technologies GasAlert Quattro BW Technologies GasAlert Max Brand

 

Sensor List:

CiTiceL 4AN Acrylonitrile (C3H3N) Sensor (AI200-800)

CiTiceL 2CF3 Carbon Monoxide (CO) Sensor

CiTiceL 4CM Carbon Monoxide (CO) Sensor (2112B2055R)

CiTiceL 4MF Carbon Monoxide (CO) Sensor (2112B2061)

CiTiceL 4CF+ Carbon Monoxide (CO) Sensor (2112B2005)

CiTiceL 4LXH Carbon Monoxide (CO) Sensor

CiTiceL 4F Carbon Monoxide (CO) Sensor

ECO-SURE 2E Carbon Monoxide (CO) Sensor (2112B3000)

CiTiceL 4COSH Carbon Monoxide / Hydrogen Sulfide (CO/H2s (COSH)) Sensor

ECO-SURE X Carbon Monoxide (CO) Sensor

CiTiceL 4CL Chlorine (Cl2) Sensor

CiTipeL 4P50 Combustible Gas Sensor

CiTipeL 4P90M Combustible Gas Sensor

CiTipeL 4P90C Combustible Gas Sensor

CiTipeL 4P75M Combustible Gas Sensor

CiTipeL 4P50C Combustible Gas Sensor

CiTipeL 4P75C Combustible Gas Sensor

CiTipeL 4P90 Combustible Gas Sensor

CiTipeL 4P50M Combustible Gas Sensor

CiTipeL 4P75C T4 Combustible Gas Sensor

CiTipeL 4P75 Combustible Gas Sensor

CiTiceL 4ETO Ethylene Oxide (C2H4O) Sensor (AT204-800)

CiTiceL 4HYT Hydrogen (H2) Sensor (AE204-803)

CiTiceL 4HN Hydrogen Cyanide (HCN) Sensor

CiTiceL 4H Hydrogen Sulfide (H2S) Sensor

CiTiceL 4H/LM Hydrogen Sulfide (H2S) Sensor

CiTiceL 4HS+ Hydrogen Sulfide (H2S) Sensor

CiTiceL 4HS/LM Hydrogen Sulfide (H2S) Sensor

CiTiceL 4ND Nitrogen Dioxide (NO2) Sensor

CiTiceL 4NT Nitric Oxide (NO) Sensor

CiTiceL 5OXLL Oxygen (O2) Sensor

CiTiceL 4OXLL Oxygen (O2) Sensor – for emissions applications

CiTiceL 4OXLL Oxygen (O2) Sensor – for industrial safety applications

CiTiceL 4OXV Oxygen (O2) Sensor (AAY80-390)

CiTiceL 4PH Phosphine (PH3) Sensor

CiTiceL 4S Sulfur Dioxide (SO2) Sensor

 

Main Specifications:

Technology: Electrochemical
Measurement Range: 1-25% vol. O2
Maximum Overload: 30% vol. O2
Output Signal: 0.10 ± 0.02 mA in Air
Response Time (T90): <15 Seconds
Zero Current (Offset): <0.6% vol. O2
Linearity: Can be considered linear in many cases.
See Operating Principles (OP-02) for further details.

Recommended Load Resistor: 100 Ω

Casing Material: ABS
Weight: <16 g
Orientation Sensitivity: <0.2% vol. O2 equivalent

Operating Temperature Range: -20°C to +50°C (up to 3 months continuous across RH range)
Recommended Storage Temp: 0°C to 20°C
Thermal Transient (Temp. plunge +22°C to -20°C): <23.5% vol. O2
Operating Pressure Range: Atmospheric ± 20%
Pressure Coefficient: <0.02% signal/mbar
Pressure Transient (60 cm H2O step change): <200% signal change
Relative Humidity Range: (at 0°C to 20°C)
Continuous: 5 to 95%RH non-condensing
Short Term: 0 to 99%RH non-condensing

Long Term Output Drift: <2% signal/month
Typically <5% over operating life
Expected Operating Life: Minimum 24 months in air