BW Clip Real Time 2 Year O2 Detector
RM 0.00
SKU: BWC2R-X
Categories: BRAND, BW Clip, Honeywell BW International Inc, Honeywell BW International Inc, Single Gas Detector, SINGLE GAS DETECTOR
Tags: BW Clip, BW CLIP O2, BW Technologies Honeywell, BWC2R-X, SINGLE GAS DETECTOR
Description
BW Clip Real Time 2 Year O2 Detector 19.5-23.5 % vol BWC2R-X
The BW Clip Real Time 2 Year O2 Detector is a lightweight and easy to handle single gas detector for oxygen. Designed for a wide range of harsh environments and extreme temperatures, this monitor has the default alarm setpoints at 19.5% vol. to 23.5% vol. BW Clip Real Time 2 Year O2 Detector includes a real-time gas level display and the ability to calibrate the device. It provides two years maintenance-free operation: just turn on the device, and it runs continuously.
Key Features:
- Default alarm setpoints: 19.5% vol.-23.5% vol.
- Alarm setpoints range: 18% vol.-25% vol.
- Measuring range: 0-25% vol.
- Temperature: -4 to +122 degrees F
- Humidity: 5% – 95% RH (non-condensing)
- Alarm: visual, vibrating, audible (95 dB), low, high
- Wide-angle flash, which alerts simultaneously with audible and vibrating alarm
- Automated self-test of battery, sensor and electronics
- Automatic logging of the 35 most recent gas events, bump test and calibration results
- Ingress Protection: IP 66/67
- Battery life: 2 years
- Surecell and Reflex Technology
- Compatible with the MicroDock II and the IntelliDoX instrument management systems (with updated Firmware)
- Compatible with hands-free Hard Hat Clip carrying accessory
- Certifications: Class I, Div. 1, Gr. A, B, C, D, Class I, Zone 0 , Gr. IIC; Ex ia IIC T4 Ga IP66/67, IECEx UL 14.0063, Ex ia IIC T4 Ga IP66/67, DEMKO 14 ATEX 1356, CE European Conformity
Specifications:
- Size: 1.6 x 2.0 x 3.4 in. / 4.1 x 5.0 x 8.7 cm
- Weight: 3.2 oz. / 92 g
- Temperature: H2S: -40 to +122°F / -40 to +50°C , CO: -22 to +122°F / -30 to +50°C , O2: -4 to +122°F / -20 to +50°C , SO2: -22 to +122°F / -30 to +50°C
- Humidity: 5% – 95% RH (non-condensing)
- Alarms: Visual, vibrating, audible (95 dB) • Low, High Tests Activated detectors automatically perform one internal diagnostic test every 24 hours.
- Typical battery life: Two years (H2S, CO, O2 or SO2) or three years (H2S or CO)
- Event logging: 35 most recent events
- Ingress Protection: IP 66/67
- Certifications and approvals : Class I, Div. 1, Gr. A, B, C, D Class I, Zone 0 , Gr. IIC 0539 II 1G, Ex ia IIC T4 Ga IP66/67, DEMKO 14 ATEX 1356, IECEx: Ex ia IIC T4 Ga IP66/67,IECEx UL 14.0063
- Part Number: BWC2R-X
Additional information
Weight | 0.2 kg |
---|