DWYER Series 629C Wet/Wet Differential Pressure Transmitter

RM 0.00

Clear

Description

Series 629C Wet/Wet Differential Pressure Transmitter, 0.5% Accuracy, NEMA 4X (IP66) Enclosure

 

The DWYER Series 629C Wet/Wet Differential Pressure Transmitter monitors differential pressure of air and compatible gases and liquids with 0.5% accuracy. The design employs dual pressure sensors converting pressure changes into a standard 4 to 20 mA output signal or field selectable voltage. DWYER Series 629C Wet/Wet Differential Pressure Transmitter small internal volume and minimal moving parts result in exceptional response and reliability. The terminal block, as well as a zero adjustment button, are easily accessed under the top cover.

 

Features

  • Powered by either DC or AC – take advantage of most readily available power source reducing installation costs
  • Optional LCD does not need a separate power supply – lowers installed cost
  • Selectable voltage range – provides flexible choice for changing design or inputs for process/HVAC controllers being used to monitor and control
  • Push button zero (versus trim pot) – more simple zeroing provides easy install and calibration reducing installation time and possibility of operator error
  • Optional LCD indicator provides local status to identify operational condition
  • Remote sensor option reduces installation labor and material

 

Specifications

  • Service: Compatible gases and liquids.
  • Wetted Materials: Without valve: 316, 316L SS. Additional wetted parts with valve option: Buna-N, silicone grease, PTFE, brass 360, copper, and reinforced copolymer.
  • Accuracy: ±0.5% FS (includes linearity, hysteresis & repeatability)
  • Stability: ±1% FS/year.
  • Temperature Limits: 0 to 200°F (-18 to 93°C).
  • Compensated Temperature Limits: 0 to 175°F (-18 to 79°C).
  • Pressure Limits: See chart on catalog page.
  • Thermal Effect: Avg 0.04%/°F (0.072%/°C) (includes zero and span).
  • Power Requirements: 2-wire: 10 to 35 VDC; 3-wire: 13 to 35 VDC or isolated 16 to 33 VAC (reverse polarity protected).
  • Output Signal: 2-wire: 4 to 20 mA; 3-wire: Field selectable 0 to 5, 1 to 5, 0 to 10, or 2 to 10 VDC.
  • Zero and Units: Push buttons inside conduit enclosure.
  • Response Time: 400 msec.
  • Loop Resistance: Current output: 0 to 1250 Ω (max), Rmax = 50(Vps-10); Voltage output: Minimum load resistance = 5 kΩ.
  • Current Consumption: 28 mA (max).
  • Electrical Connections: Removable terminal block; 1/2″ female NPT conduit.
  • Process Connections: 1/4″ female or male NPT.
  • Display: Optional 4-1/2 digit LCD field attachable display.
  • Enclosure Rating:
  • Designed to meet NEMA 4X (-RS maintains NEMA 4X on sensors and housing).
  • Mounting Orientation:
  • Not position sensitive.
  • Weight:
  • 629C-XX-CH: 10.1 oz (286 g); 629C-XX-R2-P1-E5-XX: 2.3 lbs (1.04 kg); 629C-XX-R6-P1-E5-XX: 4.55 lbs (2.06 kg).
  • Agency Approvals:
  • CE.

 

Models & Ordering

 

629C NEW! with Remote Sensors

Model Description
629C-02-R2-P1-E5-S1 Wet/wet differential pressure transmitter, range 10 psid, working pressure 20 psi, over pressure 100 psi with remote sensors and 20′ shielded cable.
629C-02-R6-P1-E5-S1 Wet/wet differential pressure transmitter, range 10 psid, working pressure 20 psi, over pressure 100 psi with remote sensors and 20′ armored cable.
629C-03-R1-P1-E5-S3 Wet/wet differential pressure transmitter, range 25 psid, working pressure 50 psi, over pressure 250 psi with remote sensors and 10′ shielded cable.
629C-03-R5-P1-E5-S3 Wet/wet differential pressure transmitter, range 25 psid, working pressure 50 psi, over pressure 250 psi with remote sensors and 10′ armored cable.
629C-05-R1-P1-E5-S3 Wet/wet differential pressure transmitter, range 100 psid, working pressure 200 psi, over pressure 500 psi with remote sensors and 10′ shielded cable.
629C-05-R5-P1-E5-S3 Wet/wet differential pressure transmitter, range 100 psid, working pressure 200 psi, over pressure 500 psi with remote sensors and 10′ armored cable.

 

Standard Transmitter with 4-20 mA Output

Model Description
629C-02-CH-P2-E5-S1 Wet/wet differential pressure transmitter, range 10 psid, working pressure 20 psi, over pressure 100 psi.
629C-03-CH-P2-E5-S1 Wet/wet differential pressure transmitter, range 25 psid, working pressure 50 psi, over pressure 120 psi.
629C-04-CH-P2-E5-S1 Wet/wet differential pressure transmitter, range 50 psid, working pressure 100 psi, over pressure 250 psi.
629C-05-CH-P2-E5-S1 Wet/wet differential pressure transmitter, range 100 psid, working pressure 200 psi, over pressure 500 psi.

 

Standard Transmitter with Selectable Voltage Output

Model Description
629C-02-CH-P2-E5-S3 Wet/wet differential pressure transmitter, range 10 psid, conduit housing, 1/4″ NPT female process connections, 0-10 V output.
629C-03-CH-P2-E5-S3 Wet/wet differential pressure transmitter, range 25 psid, conduit housing, 1/4″ NPT female process connections, 0-10 V output.
629C-04-CH-P2-E5-S3 Wet/wet differential pressure transmitter, range 50 psid, conduit housing, 1/4″ NPT female process connections, 0-10 V output.
629C-05-CH-P2-E5-S3 Wet/wet differential pressure transmitter, range 100 psid, conduit housing, 1/4″ NPT female process connections, 0-10 V output.

 

Transmitter with 3-way Valve Manifold Assembly with 4-20 mA

Model Description
629C-02-CH-P2-E5-S1-3 Wet/wet differential pressure transmitter with 3-way valve package, range 10 psid, conduit housing, NEMA 4X, 1/4″ female NPT, 1/2″ female NPT conduit, 4-20 mA
629C-03-CH-P2-E5-S1-3 Wet/wet differential pressure transmitter with 3-way valve package, range 25 psid, conduit housing, NEMA 4X, 1/4″ female NPT, 1/2″ female NPT conduit, 4-20 mA
629C-04-CH-P2-E5-S1-3 Wet/wet differential pressure transmitter with 3-way valve package, range 50 psid, conduit housing, NEMA 4X, 1/4″ female NPT, 1/2″ female NPT conduit, 4-20 mA
629C-05-CH-P2-E5-S1-3 Wet/wet differential pressure transmitter with 3-way valve package, range 100 psid, conduit housing, NEMA 4X, 1/4″ female NPT, 1/2″ female NPT conduit, 4-20 mA

 

Transmitter with 3-way Manifold Assembly with Selectable Voltage Output

Model Description
629C-02-CH-P2-E5-S3-3 Wet/wet differential pressure transmitter with 3-way valve package, range 10 psid, working pressure 50 psi, over pressure 250 psi.
629C-03-CH-P2-E5-S3-3 Wet/wet differential pressure transmitter with 3-way valve package, range 25 psid, working pressure 50 psi, over pressure 250 psi.
629C-04-CH-P2-E5-S3-3 Wet/wet differential pressure transmitter with 3-way valve package, range 50 psid, working pressure 100 psi, over pressure 250 psi.
629C-05-CH-P2-E5-S3-3 Wet/wet differential pressure transmitter with 3-way valve package, range 100 psid, working pressure 200 psi, over pressure 500 psi.

 

 

 

Additional information

Model

629C-02-R2-P1-E5-S1, 629C-02-R6-P1-E5-S1, 629C-03-R1-P1-E5-S3, 629C-03-R5-P1-E5-S3, 629C-05-R1-P1-E5-S3, 629C-05-R5-P1-E5-S3, 629C-02-CH-P2-E5-S1, 629C-03-CH-P2-E5-S1, 629C-04-CH-P2-E5-S1, 629C-05-CH-P2-E5-S1, 629C-02-CH-P2-E5-S3, 629C-03-CH-P2-E5-S3, 629C-04-CH-P2-E5-S3, 629C-05-CH-P2-E5-S3, 629C-02-CH-P2-E5-S1-3, 629C-03-CH-P2-E5-S1-3, 629C-04-CH-P2-E5-S1-3, 629C-05-CH-P2-E5-S1-3, 629C-02-CH-P2-E5-S3-3, 629C-03-CH-P2-E5-S3-3, 629C-04-CH-P2-E5-S3-3, 629C-05-CH-P2-E5-S3-3