MKS BARATRON TYPE 141 VACUUM SWITCH

RM 0.00

Clear

Description

BARATRON TYPE 141 VACUUM SWITCH

 

The 141A Absolute Pressure Switch offers fast, accurate, and reliable protection for vacuum equipment and processes. Designed for applications where a DC signal output is not required, the 141A has relay outputs that are easily interfaced with alarms, valve actuators, computers, process controllers, and other protection devices.

 

  • Fully adjustable set point for flexibility
  • All-metal, all-welded Inconel® and stainless steel construction for corrosion resistance
  • Fast response switching – 20 msec

 

Specifications

  • Type
    Pressure Switch
  • Measurement Type
    Absolute
  • Full Scale Pressure Ranges
    1, 2, 10, 100, 1000 Torr (mmHg) absolute
  • Set Point Range
    0.2% to 100% of Full Scale
  • Sensor Temperature
    Ambient
  • Accuracy
    ±0.5% of Full Scale Range (± temperature coefficients)
  • Zero Temperature Coefficient
    ±0.04% of Full Scale/°C
  • Span Temperature Coefficient
    ±0.06% of set point/°C
  • Operating Temperature Range
    0° to 50°C
  • Response Time
    < 20 msec from 0 to Full Scale
  • Relay Contact Ratings
    DPDT, 2 amps @ 30 VDC or 1 amp @ 120 VAC resistive
  • Internal Volume
    7.0 cc (5K-25K Torr units have an 8.5 cc volume)
  • Overpressure
    120% of Full Scale or 35 psia (1000 mmHg), whichever is larger (1 and 2 Torr Full Scale units have a max. overpressure of 25 psia)
  • Power Requirements
    20 to 30 VDC, 72 mA
  • Compliance
    Compliant to EMC Directive 2014/30/EU

 

Model

MODEL

FULL SCALE RANGE

FITTING TYPE

RELAY MODE

141AA-00001AA Absolute Pressure Switch, 1 Torr, 0.5 in. Tube, Standard DPDT Relay 1 Torr 0.5 in. OD tube Energizes above set point
141AA-00001AB Absolute Pressure Switch, 1 Torr, 0.5 in. Tube, Fail Safe DPDT Relay 1 Torr 0.5 in. OD tube Energizes below set point
141AA-00001BA Absolute Pressure Switch, 1 Torr, 8 VCR Female, Standard DPDT Relay 1 Torr 8 VCR female Energizes above set point
141AA-00001BB Absolute Pressure Switch, 1 Torr, 8 VCR Female, Fail Safe DPDT Relay 1 Torr 8 VCR female Energizes below set point
141AA-00001DA Absolute Pressure Switch, 1 Torr, ISO-KF, Standard DPDT Relay 1 Torr NW16 ISO-KF Energizes above set point
141AA-00001DB Absolute Pressure Switch, 1 Torr, NW16 ISO-KF, Fail Safe DPDT Relay 1 Torr NW16 ISO-KF Energizes below set point
141AA-00010AA Absolute Pressure Switch, 10 Torr, 0.5 in. Tube, Standard DPDT Relay 10 Torr 0.5 in. OD tube Energizes above set point
141AA-00010AB Absolute Pressure Switch, 10 Torr, 0.5 in. Tube, Fail Safe DPDT Relay 10 Torr 0.5 in. OD tube Energizes below set point
141AA-00010BA Absolute Pressure Switch, 10 Torr, 8 VCR Female, Standard DPDT Relay 10 Torr 8 VCR female Energizes above set point
141AA-00010BB Absolute Pressure Switch, 10 Torr, 8 VCR Female, Fail Safe DPDT Relay 10 Torr 8 VCR female Energizes below set point
141AA-00010DA Absolute Pressure Switch, 10 Torr, NW16 ISO-KF, Standard DPDT Relay 10 Torr NW16 ISO-KF Energizes above set point
141AA-00010DB Absolute Pressure Switch, 10 Torr, NW16 ISO-KF, Fail Safe DPDT Relay 10 Torr NW16 ISO-KF Energizes below set point
141AA-00100AA Absolute Pressure Switch, 100 Torr, 0.5 in. Tube, Standard DPDT Relay 100 Torr 0.5 in. OD tube Energizes above set point
141AA-00100AB Absolute Pressure Switch, 100 Torr, 0.5 in. Tube, Fail Safe DPDT Relay 100 Torr 0.5 in. OD tube Energizes below set point
141AA-00100BA Absolute Pressure Switch, 100 Torr, 8 VCR Female, Standard DPDT Relay 100 Torr 8 VCR female Energizes above set point
141AA-00100BB Absolute Pressure Switch, 100 Torr, 8 VCR Female, Fail Safe DPDT Relay 100 Torr 8 VCR female Energizes below set point
141AA-00100DA Absolute Pressure Switch, 100 Torr, NW16 ISO-KF, Standard DPDT Relay 100 Torr NW16 ISO-KF Energizes above set point
141AA-00100DB Absolute Pressure Switch, 100 Torr, NW16 ISO-KF, Fail Safe DPDT Relay 1000 Torr NW16 ISO-KF Energizes below set point
141AA-01000AA Absolute Pressure Switch, 1000 Torr, 0.5 in. Tube, Standard DPDT Relay 1000 Torr 0.5 in. OD tube Energizes above set point
141AA-01000AB Absolute Pressure Switch, 1000 Torr, 0.5 in. Tube, Fail Safe DPDT Relay 1000 Torr 0.5 in. OD tube Energizes below set point
141AA-01000BA Absolute Pressure Switch, 1000 Torr, 8 VCR Female, Standard DPDT Relay 1000 Torr 8 VCR female Energizes above set point
141AA-01000BB Absolute Pressure Switch, 1000 Torr, 8 VCR Female, Fail Safe DPDT Relay 1000 Torr 8 VCR female Energizes below set point
141AA-01000DA Absolute Pressure Switch, 1000 Torr, NW16 ISO-KF, Standard DPDT Relay 1000 Torr NW16 ISO-KF Energizes above set point
141AA-01000DB Absolute Pressure Switch, 1000 Torr, NW!6 ISO-KF, Fail Safe DPDT Relay 1000 Torr NW16 ISO-KF Energizes below set point

 

 

Additional information

Weight 0.3 kg
Model

141AA-00001AA, 141AA-00001AB, 141AA-00001BA, 141AA-00001BB, 141AA-00001DA, 141AA-00001DB, 141AA-00010AA, 141AA-00010AB, 141AA-00010BA, 141AA-00010BB, 141AA-00010DA, 141AA-00010DB, 141AA-00100AA, 141AA-00100AB, 141AA-00100BA, 141AA-00100BB, 141AA-00100DA, 141AA-00100DB, 141AA-01000AA, 141AA-01000AB, 141AA-01000BA, 141AA-01000BB, 141AA-01000DA, 141AA-01000DB