CANNON Zeitfuchs Transparent Viscometer

RM 0.00

Clear

Description

ASTM D445, ISO 3104

 

CANNON Zeitfuchs Transparent Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Filling, measurement and cleaning do not require removal from the constant temperature bath. Minimum sample volume is 15 mL. Minimum bath depth is 292 mm (11.5 in). Both calibrated and uncalibrated viscometers are available and provided with permanently attached round or rectangular metal holders. CANNON Zeitfuchs Transparent Viscometer Calibrated viscometers also include a certificate of calibration and instruction sheet.

Use of high quality instruments ensures test reliability and accuracy, and all CANNON glass capillary viscometers are traceable to a NIST calibration and manufactured in our ISO 9001-registered, A2LA-accredited laboratory. CANNON Instrument Company has been making glass capillary viscometers since 1938 and because no single viscometer is ideally suited to every application, we offer a wide variety of glass capillary viscometers. Our experienced staff is happy to assist you with viscometer selection. Viscometer options include:

Transparent
For transparent/translucent liquids
Suspended Level
For transparent/translucent liquids. Ideal for testing at multiple temperatures because they have the same viscometer constant at all temperatures.
Dilution
For dilution of polymer solutions to provide an estimate of the molecular size and shape.
Reverse Flow
For transparent and opaque liquids. Must be cleaned, dried and refilled between repeat determinations.
Vacuum
A special type of reverse-flow viscometer for highly viscous samples (transparent or opaque). Accurately controlled vacuum is required to pull the liquid through the viscometer.

Zeitfuchs Transparent Viscometers

Catalog Number    Size   
Approximate
Constant (cSt/s)
Viscosity Range
(cSt/s)
with round 
metal holders*
with rectangular
metal holders**
    uncalibrated         calibrated         uncalibrated         calibrated     low high
9723-A50 9723-B50 9723-C50 9723-D50 1 0.003 0.6 3.0
9723-A55 9723-B55 9723-C55 9723-D55 2 0.01 2.0 10
9723-A60 9723-B60 9723-C60 9723-D60 3 0.03 6.0 30
9723-A65 9723-B65 9723-C65 9723-D65 4 0.1 20 100
9723-A70 9723-B70 9723-C70 9723-D70 5 0.3 60 300
9723-A75 9723-B75 9723-C75 9723-D75 6 1.0 200 1000
9723-A80 9723-B80 9723-C80 9723-D80 7 3.0 600 3000
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
*round holder is compatible with a 51 mm (2 in) diameter port
**rectangular holder is compatible with a bath opening of 25 mm x 48 mm (1 in x 1.9 in)

Additional information

Weight 1 kg
Model