Series 608 Intrinsically Safe Differential Pressure Transmitter, Ranges Down to 0.1″ w.c., FM

Approved, NEMA 4X

 

The DWYER Series 608 Differential Pressure Transmitter convert positive, negative (vacuum), or differential pressures of clean, dry air or other non-conductive, non-corrosive gases into a standard two wire, 4-20 mA output signal. DWYER Series 608 Differential Pressure Transmitter use of an ultra thin silicon diaphragm enables precision measurement of differential pressures as low as 0.1″ of w.c. while withstanding high static working pressures up to 100 psig (6.89 bar). The Series 608 transmitters are FM approved intrinsically safe for use in the specified hazardous locations when used with an approved intrinsic safety barrier.

 

Features

  • High accuracy at low pressure ranges provides exceptional measurement for ensuring tight-control and minimizing costly out of specification conditions
  • Intrinsically safe for use in the specified hazardous locations meets specifications where pressure transmission and safety cannot be compromised
  • NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists

 

Specifications

  • Service: Clean/dry air and compatible combustible gases (see Agency Approvals for FM ratings).
  • Wetted Materials: Consult factory.
  • Accuracy: ±0.5% or ±0.25% full scale.
  • Stability: ±0.5% F.S./yr.
  • Pressure Limits: 100 psig (6.89 bar); 15 psid (1.03 bar).
  • Temperature Limits: -20 to 185°F (-28 to 85°C).
  • Compensated Temperature Range: 0 to 160°F (-18 to 71°C).
  • Thermal Effect: 0.5% Accuracy: ±0.02% F.S./°F; 0.25% Accuracy: ±0.01% F.S./°F.
  • Power Requirements: 12 to 30 VDC (2-wire).
  • Output Signal: 4 to 20 mA DC.
  • Zero and Span Adjustments: Potentiometers for zero and span.
  • Response Time: 250 ms.
  • Loop Resistance: DC: 0 to 1045 Ω maximum.
  • Electrical Connections: Screw terminals: two 1/2″ female NPT conduit.
  • Process Connections: Two 1/4″ female NPT.
  • Enclosure Rating: NEMA 4X (IP65).
  • Mounting Orientation: Not position sensitive.
  • Weight: 2 lb (0.9 kg).
  • Agency Approvals: FM approved intrinsically safe for use in Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1 when wire with approved intrinsically safe barrier. Entity parameters: Vmax=36 VDC; Imax=250 mA; C=12 nF; L=0 mH.

 

Models & Ordering

0.5% Accuracy

Model Description
608-00 Differential pressure transmitter, range 0-0.1″ w.c.
608-00B Differential pressure transmitter, range 0.1-0-0.1″ w.c.
608-01 Differential pressure transmitter, range 0-0.25″ w.c.
608-01B Differential pressure transmitter, range 0.25-0-0.25″ w.c.
608-02 Differential pressure transmitter, range 0-0.5″ w.c.
608-02B Differential pressure transmitter, range 0.5-0-0.5″ w.c.
608-03 Differential pressure transmitter, range 0-1.0″ w.c.
608-03B Differential pressure transmitter, range 1.0-0-1.0″ w.c.
608-04 Differential pressure transmitter, range 0-2.0″ w.c.
608-04B Differential pressure transmitter, range 2.0-0-2.0″ w.c.
608-05 Differential pressure transmitter, range 0-5.0″ w.c.
608-05B Differential pressure transmitter, range 5.0-0-5.0″ w.c.
608-06 Differential pressure transmitter, range 0-10.0″ w.c.
608-07 Differential pressure transmitter, range 0-25.0″ w.c.

 

0.25% Accuracy

Model Description
608-10 Differential pressure transmitter, range 0-0.1″ w.c.
608-10B Differential pressure transmitter, range 0.1-0-0.1″ w.c.
608-11 Differential pressure transmitter, range 0-0.25″ w.c.
608-11B Differential pressure transmitter, range 0.25-0-0.25″ w.c.
608-12 Differential pressure transmitter, range 0-0.5″ w.c.
608-12B Differential pressure transmitter, range 0.5-0-0.5″ w.c.
608-13 Differential pressure transmitter, range 0-1.0″ w.c.
608-13B Differential pressure transmitter, range 1.0-0-1.0″ w.c.
608-14 Differential pressure transmitter, range 0-2.0″ w.c.
608-14B Differential pressure transmitter, range 2.0-0-2.0″ w.c.
608-15 Differential pressure transmitter, range 0-5.0″ w.c.
608-15B Differential pressure transmitter, range 5.0-0-5.0″ w.c.
608-16 Differential pressure transmitter, range 0-10.0″ w.c.
608-17 Differential pressure transmitter, range 0-25.0″ w.c.

 

 

 

Additional information

Model

608-00, 608-00B, 608-01, 608-01B, 608-02, 608-02B, 608-03, 608-03B, 608-04, 608-04B, 608-05, 608-05B, 608-06, 608-07, 608-10, 608-10B, 608-11, 608-11B, 608-12, 608-12B, 608-13, 608-13B, 608-14, 608-14B, 608-15, 608-15B, 608-16, 608-17