{"id":9423,"date":"2022-06-22T08:39:29","date_gmt":"2022-06-22T00:39:29","guid":{"rendered":"https:\/\/ancor.biz\/?post_type=product&#038;p=9423"},"modified":"2025-08-18T12:43:28","modified_gmt":"2025-08-18T04:43:28","slug":"dwyer-series-672-low-pressure-transducer","status":"publish","type":"product","link":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/","title":{"rendered":"DWYER Series 672 Low Pressure Transducer"},"content":{"rendered":"<h1>Series 672 Low Pressure Transducer, Single Pressure Connection, Ranges Down to 10 in w.c.<\/h1>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/ancor.biz\/index.php\/product-category\/brand\/dwyer-instruments-brand\/\">DWYER<\/a> Series 672 Low Pressure Transducer is a perfect solution to any application where a very accurate low pressure transducer is necessary. Using variable capacitance technology, the Series 672 is designed to measure pressures as low as 10 in w.c. up to 400 in w.c., very low ranges for a single connection pressure transducer. The DWYER Series 672 Low Pressure <a href=\"https:\/\/intl.dwyer-inst.com\/Product\/DiscontinuedProducts\/Pressure\/Series672?Query=%20672\">Transducer<\/a> also features a 0.25% F.S. accuracy. Use the Series 672 in liquid level, flood warning, waste water, clean room, and open channel flow applications.<\/p>\n<p>&nbsp;<\/p>\n<p class=\"sub_heading\">Product Applications<\/p>\n<ul class=\"list-details inline product_feature\">\n<li>Liquid level<\/li>\n<li>Flood warning<\/li>\n<li>Waste water<\/li>\n<li>Clean room<\/li>\n<li>Open flow applications<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<section id=\"features\" class=\"ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-4\" aria-expanded=\"true\" aria-hidden=\"false\">\n<p class=\"tab-heading\">Features<\/p>\n<ul>\n<li>Low range high accuracy provides precise control for process applications<\/li>\n<\/ul>\n<\/section>\n<p>&nbsp;<\/p>\n<section id=\"specs\" class=\"ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-3\" aria-expanded=\"true\" aria-hidden=\"false\">\n<p class=\"tab-heading\">Specifications<\/p>\n<ul class=\"list-specs lined\">\n<li>Service: Compatible liquids and gases.<\/li>\n<li class=\"title\">Wetted Materials: 318 Duplex SS, Ceramic, Fluoroelastomer (FKM).<\/li>\n<li class=\"title\">Housing Material: 318 Stainless Steel.<\/li>\n<li class=\"title\">Accuracy: \u00b10.25% F.S. (RSS). Includes non-linearity, hysteresis, and non-repeatability.<\/li>\n<li class=\"title\">Stability: 0.25% F.S.\/1 year.<\/li>\n<li class=\"title\">Temperature Limits: -40 to 212\u00b0F (-40 to 100\u00b0C).<\/li>\n<li class=\"title\">Compensated Temperature Limits: -5 to 140\u00b0F (-20 to 60\u00b0C).<\/li>\n<li class=\"title\">Pressure Limits: 29 psi (2 bar) for up to 85&#8243; w.c. (0.2 bar) ranges; 58 psi (4 bar) for 85&#8243; to 140&#8243; w.c. (0.2 to 0.35 bar); 73 psi (5 bar) for 141&#8243; to 400&#8243; w.c. (0.35 to 1 bar).<\/li>\n<li class=\"title\">Thermal Effects: Zero: 1.0%F.S.\/100\u00b0F (2.0%F.S.\/100\u00b0C); Span: 1.0%F.S.\/100\u00b0F (2.0%F.S.\/100\u00b0C).<\/li>\n<li class=\"title\">Power Requirements: 4-20 mA: 9-35 VDC; 0-5 VDC: 7.5-35 VDC.<\/li>\n<li class=\"title\">Output Signal: 4-20 mA (2-wire) or 0-5 VDC (3-wire).<\/li>\n<li class=\"title\">Zero &amp; Span Adjustment: \u00b110% F.S. each (by Potentiometer).<\/li>\n<li class=\"title\">Response Time: 5 ms.<\/li>\n<li class=\"title\">Max Loop Resistance: 1.325 k\u03a9.<\/li>\n<li class=\"title\">Electrical Connections: Large DIN 43650 connector with mating plug.<\/li>\n<li class=\"title\">Process Connection: 1\/4&#8243;-18 NPT male.<\/li>\n<li class=\"title\">Enclosure Rating: NEMA 4X (IP65).<\/li>\n<li class=\"title\">Weight: 11.6 oz (330 g).<\/li>\n<li class=\"title\">Agency Approval: CE.<\/li>\n<\/ul>\n<\/section>\n<p>&nbsp;<\/p>\n<h2 class=\"tab-heading\">Models &amp; Ordering<\/h2>\n<p>4-20 mA Output, 2-wire<\/p>\n<table class=\"product-table\">\n<tbody>\n<tr>\n<th class=\"model-number\" nowrap=\"nowrap\" width=\"\">Model<\/th>\n<th class=\"description\" width=\"\">Description<\/th>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-1-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-10&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-2-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-15&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-3-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-25&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-4-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-50&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-5-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-100&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-6-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-150&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-7-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-200&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-8-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-300&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-9-A<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-400&#8243; w.c., 4-20 mA output.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>0-5 VDC Output, 3-wire<\/p>\n<table class=\"product-table\">\n<tbody>\n<tr>\n<th class=\"model-number\" nowrap=\"nowrap\" width=\"\">Model<\/th>\n<th class=\"description\" width=\"\">Description<\/th>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-1-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-10&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-2-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-15&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-3-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-25&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-4-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-50&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-5-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-100&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-6-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-150&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-7-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-200&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-8-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-300&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<tr>\n<td class=\"model-number\" nowrap=\"nowrap\" width=\"\">672-9-V<\/td>\n<td class=\"description\" width=\"\">Low pressure transducer, 0-400&#8243; w.c., 0-5 VDC output.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Series 672 Low Pressure Transducer, Single Pressure Connection, Ranges Down to 10 in w.c. &nbsp; DWYER Series 672 Low Pressure Transducer is a perfect solution to any application where a very accurate low pressure transducer is necessary. Using variable capacitance technology, the Series 672 is designed to measure pressures as low as 10 in w.c. &#8230; <a title=\"DWYER Series 672 Low Pressure Transducer\" class=\"read-more\" href=\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/\" aria-label=\"More on DWYER Series 672 Low Pressure Transducer\">Read more<\/a><\/p>\n","protected":false},"featured_media":9424,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"spay_email":""},"class_list":["post-9423","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-brand","product_cat-dwyer-pressure-transmitter","product_cat-dwyer-instruments-dwyer-omega","product_cat-dwyer-instruments-brand","product_cat-dwyer-omega","product_cat-pressure-transmitter","product_cat-pressure-transmitter-dwyer-instruments-brand","product_cat-pressure-transmitter-dwyer-instruments-dwyer-omega","product_cat-single-pressure-pressure-transmitter","product_tag-672-1-a","product_tag-672-1-v","product_tag-672-2-a","product_tag-672-2-v","product_tag-672-3-a","product_tag-672-3-v","product_tag-672-4-a","product_tag-672-4-v","product_tag-672-5-a","product_tag-672-5-v","product_tag-672-6-a","product_tag-672-6-v","product_tag-672-7-a","product_tag-672-7-v","product_tag-672-8-a","product_tag-672-8-v","product_tag-672-9-a","product_tag-672-9-v","product_tag-dwyer-series-672-low-pressure-transducer","product_tag-series-672-pressure-transducer","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","do-quantity-buttons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DWYER Series 672 Low Pressure Transducer - Ancor Sdn Bhd<\/title>\n<meta name=\"description\" content=\"DWYER Series 672 Low Pressure Transducer 672-1-A, 672-1-V, 672-2-A, 672-2-V, 672-3-A, 672-3-V, 672-4-A, 672-4-V, 672-5-A, 672-5-V, 672-6-A, 672-6-V, 672-7-A, 672-7-V, 672-8-A, 672-8-V, 672-9-A, 672-9-V\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DWYER Series 672 Low Pressure Transducer - Ancor Sdn Bhd\" \/>\n<meta property=\"og:description\" content=\"DWYER Series 672 Low Pressure Transducer 672-1-A, 672-1-V, 672-2-A, 672-2-V, 672-3-A, 672-3-V, 672-4-A, 672-4-V, 672-5-A, 672-5-V, 672-6-A, 672-6-V, 672-7-A, 672-7-V, 672-8-A, 672-8-V, 672-9-A, 672-9-V\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/\" \/>\n<meta property=\"og:site_name\" content=\"Ancor Sdn Bhd\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-18T04:43:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/\",\"url\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/\",\"name\":\"DWYER Series 672 Low Pressure Transducer - Ancor Sdn Bhd\",\"isPartOf\":{\"@id\":\"https:\/\/ancor.biz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif\",\"datePublished\":\"2022-06-22T00:39:29+00:00\",\"dateModified\":\"2025-08-18T04:43:28+00:00\",\"description\":\"DWYER Series 672 Low Pressure Transducer 672-1-A, 672-1-V, 672-2-A, 672-2-V, 672-3-A, 672-3-V, 672-4-A, 672-4-V, 672-5-A, 672-5-V, 672-6-A, 672-6-V, 672-7-A, 672-7-V, 672-8-A, 672-8-V, 672-9-A, 672-9-V\",\"breadcrumb\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#primaryimage\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ancor.biz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/ancor.biz\/index.php\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"DWYER Series 672 Low Pressure Transducer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ancor.biz\/#website\",\"url\":\"https:\/\/ancor.biz\/\",\"name\":\"Ancor Sdn Bhd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/ancor.biz\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ancor.biz\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ancor.biz\/#organization\",\"name\":\"Ancor Sdn Bhd\",\"url\":\"https:\/\/ancor.biz\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"width\":600,\"height\":65,\"caption\":\"Ancor Sdn Bhd\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DWYER Series 672 Low Pressure Transducer - Ancor Sdn Bhd","description":"DWYER Series 672 Low Pressure Transducer 672-1-A, 672-1-V, 672-2-A, 672-2-V, 672-3-A, 672-3-V, 672-4-A, 672-4-V, 672-5-A, 672-5-V, 672-6-A, 672-6-V, 672-7-A, 672-7-V, 672-8-A, 672-8-V, 672-9-A, 672-9-V","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/","og_locale":"en_US","og_type":"article","og_title":"DWYER Series 672 Low Pressure Transducer - Ancor Sdn Bhd","og_description":"DWYER Series 672 Low Pressure Transducer 672-1-A, 672-1-V, 672-2-A, 672-2-V, 672-3-A, 672-3-V, 672-4-A, 672-4-V, 672-5-A, 672-5-V, 672-6-A, 672-6-V, 672-7-A, 672-7-V, 672-8-A, 672-8-V, 672-9-A, 672-9-V","og_url":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/","og_site_name":"Ancor Sdn Bhd","article_modified_time":"2025-08-18T04:43:28+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif","type":"image\/gif"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/","url":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/","name":"DWYER Series 672 Low Pressure Transducer - Ancor Sdn Bhd","isPartOf":{"@id":"https:\/\/ancor.biz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#primaryimage"},"image":{"@id":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#primaryimage"},"thumbnailUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif","datePublished":"2022-06-22T00:39:29+00:00","dateModified":"2025-08-18T04:43:28+00:00","description":"DWYER Series 672 Low Pressure Transducer 672-1-A, 672-1-V, 672-2-A, 672-2-V, 672-3-A, 672-3-V, 672-4-A, 672-4-V, 672-5-A, 672-5-V, 672-6-A, 672-6-V, 672-7-A, 672-7-V, 672-8-A, 672-8-V, 672-9-A, 672-9-V","breadcrumb":{"@id":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#primaryimage","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/06\/Dwyer-Series-672-Low-Pressure-Transducer.gif","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/ancor.biz\/index.php\/product\/dwyer-series-672-low-pressure-transducer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ancor.biz\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/ancor.biz\/index.php\/shop\/"},{"@type":"ListItem","position":3,"name":"DWYER Series 672 Low Pressure Transducer"}]},{"@type":"WebSite","@id":"https:\/\/ancor.biz\/#website","url":"https:\/\/ancor.biz\/","name":"Ancor Sdn Bhd","description":"","publisher":{"@id":"https:\/\/ancor.biz\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ancor.biz\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ancor.biz\/#organization","name":"Ancor Sdn Bhd","url":"https:\/\/ancor.biz\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","width":600,"height":65,"caption":"Ancor Sdn Bhd"},"image":{"@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/9423","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/9423\/revisions"}],"predecessor-version":[{"id":50285,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/9423\/revisions\/50285"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media\/9424"}],"wp:attachment":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media?parent=9423"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}