{"id":51368,"date":"2024-10-10T14:40:58","date_gmt":"2024-10-10T06:40:58","guid":{"rendered":"https:\/\/ancor.biz\/?post_type=product&#038;p=51368"},"modified":"2025-01-23T10:32:57","modified_gmt":"2025-01-23T02:32:57","slug":"medc-ph1-pull-handle-call-point-range","status":"publish","type":"product","link":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/","title":{"rendered":"MEDC PH1 Pull Handle Call Point Range"},"content":{"rendered":"<h1 class=\"product-family-card__header b-heading-h1\">MEDC PH1 Pull Handle Call Point Range<\/h1>\n<p>&nbsp;<\/p>\n<div class=\"product-family-card__description b-body-copy\">\n<p>Eaton&#8217;s Crouse-Hinds series <a href=\"https:\/\/www.eaton.com\/us\/en-us\/site-search.html.searchTerm$medc%20manual%20alarm%20call%20point.tabs$all.html\">MEDC<\/a>\u00a0PH1 Pull Handle <a href=\"https:\/\/ancor.biz\/index.php\/product-category\/brand\/eaton-medc\/manual-alarm-call-points-eaton-medc\/\">Call Point<\/a> Range is designed for use in potentially explosive atmospheres. It&#8217;s suitable for marine and both onshore and offshore environments in the oil, gas and petrochemical industries.<\/p>\n<p>The PH1 has double activation with large \u201cLift\u201d and \u201cPull\u201d handles, making it perfect for withstanding high winds and sandstorms typical of harsh and hazardous environments. The GRP enclosure is suitable for offshore or onshore where light weight combined with a high level of corrosion resistance is required and the rugged pull handle can be used with heavy duty gloves.<\/p>\n<\/div>\n<div class=\"title aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-title eaton-title--default eaton-title--inset \">\n<div class=\"container\">\n<h4><\/h4>\n<h4 class=\"eaton-title__headline\">Design features<\/h4>\n<ul>\n<li>Certified temperature from\u00a0 -58\u00b0F to + 158\u00b0F, -55\u00b0C to +70\u00b0C*<\/li>\n<li>Corrosion free GRP construction*<\/li>\n<li>Optional in line, end of line resistors and diodes<\/li>\n<li>Retained stainless steel cover screws<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"divider aem-GridColumn aem-GridColumn--default--12\">\n<h4><\/h4>\n<h4 class=\"eaton-divider\">Standard materials<\/h4>\n<\/div>\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<div class=\"text aem-GridColumn aem-GridColumn--default--12\">\n<div class=\"eaton-text-default\">\n<div class=\"container\">\n<div class=\"eaton-text-default__content rich-text-container overlapping__anchor\">\n<ul>\n<li>Body\/covers\/handles: GRP (glass reinforced polyester) UL Class I, Div. 1 inner cover: 316 (ANC4B) stainless steel<\/li>\n<li>Fixings: stainless steel grade 316<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><strong>Specifications<\/strong><\/p>\n<ul>\n<li>Material: Body\/covers\/handles:- GRP (glass reinforced polyester).<\/li>\n<li>UL Class I, Div. 1 Inner Cover: 316 (ANC4B) Stainless Steel.<\/li>\n<li>Fixings: Stainless steel grade 316.<\/li>\n<li>Finish: Cover: natural red, Body:- natural black.<\/li>\n<li>Handles: natural white.<\/li>\n<li>Cover may be painted to customer\u2019s requirements.<\/li>\n<li>Voltage: 0-50Vdc, 0-254Vac.<\/li>\n<li>Switch Rating: 1 or 2 c\/o switches, 254V, 3A max.<\/li>\n<li>Weight: UL Class I, Div 2, ATEX, IECEx &amp; UW: Gross weight 3.2Kg.<\/li>\n<li>Net weight 2.6Kg.<\/li>\n<li>UL Class I, Div. 1: Gross weight 4.4 Kg. Net weight 3.8Kg.<\/li>\n<li>Certified Temp: ATEX &amp; IECEx: -55\u00baC to +70\u00baC.<\/li>\n<li>UL Class I, Divs. 1 &amp; 2, UW: -50\u00baC to +70\u00baC<\/li>\n<li>Ingress Protection: NEMA 4X &amp; 6. IP66 &amp; IP67.<\/li>\n<li>Entries: UL Class I, Div. 1 &#8211; Max 1 per face. Up to 2 x 1\/2\u201d NPT or 3\/4\u201d NPT. Positions 2 &amp; 5 only.<\/li>\n<li>UL Class I, Div. 2, UW: Up to 2 x 1\/2\u201d or 3\/4\u201d NPT. 3\/4\u201d NPT, Max. 1 per face &amp; positions 2 &amp; 5 only. ATEX, IECEx &#8211; Max 2 per face. Up to 2 x M20 or M25, up to 2 x 1\/2\u201d or 3\/4\u201d NPT.<\/li>\n<li>Terminals: 6 x 2.5mm2 as standard. Contact MEDC for options.<\/li>\n<li>Earth Continuity: Earth continuity is provided by internal plate.<\/li>\n<li>Duty Labels: \u2018Burning house\u2019 label fitted as standard on red units.<\/li>\n<li>Tag Label: worded to customers requirements.<\/li>\n<li>Addr. module: SIGA-CT1 (To be free issued by customer).<\/li>\n<li>Resistors: Various configurations available, 470 Ohms minimum.<\/li>\n<li>Diodes: Various configurations available.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Catalog<\/strong><\/p>\n<a href=\"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/Eaton-MEDC-PH1-Manual-Alarm-Call-Point-Datasheet.pdf\" class=\"pdfemb-viewer\" style=\"\" data-width=\"max\" data-height=\"max\"  data-toolbar=\"bottom\" data-toolbar-fixed=\"off\">Eaton MEDC PH1 Manual Alarm Call Point Datasheet<br\/><\/a>\n","protected":false},"excerpt":{"rendered":"<p>MEDC PH1 Pull Handle Call Point Range &nbsp; Eaton&#8217;s Crouse-Hinds series MEDC\u00a0PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres. It&#8217;s suitable for marine and both onshore and offshore environments in the oil, gas and petrochemical industries. The PH1 has double activation with large \u201cLift\u201d and \u201cPull\u201d handles, making it &#8230; <a title=\"MEDC PH1 Pull Handle Call Point Range\" class=\"read-more\" href=\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/\" aria-label=\"More on MEDC PH1 Pull Handle Call Point Range\">Read more<\/a><\/p>\n","protected":false},"featured_media":51370,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"spay_email":""},"class_list":["post-51368","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-brand","product_cat-eaton-medc","product_cat-eaton-medc-manual-alarm-call-points","product_cat-manual-alarm-call-points","product_cat-manual-alarm-call-points-eaton-medc","product_tag-eaton-malaysia","product_tag-eaton-medc-malaysia","product_tag-manual-call-point","product_tag-medc-ph1","product_tag-medc-ph1-call-point","product_tag-medc-ph1-pull-handle-call-point","product_tag-medc-ph1-pull-handle-call-point-range","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","do-quantity-buttons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>MEDC PH1 Pull Handle Call Point Range - Ancor Sdn Bhd<\/title>\n<meta name=\"description\" content=\"MEDC PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MEDC PH1 Pull Handle Call Point Range - Ancor Sdn Bhd\" \/>\n<meta property=\"og:description\" content=\"MEDC PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/\" \/>\n<meta property=\"og:site_name\" content=\"Ancor Sdn Bhd\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-23T02:32:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/\",\"url\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/\",\"name\":\"MEDC PH1 Pull Handle Call Point Range - Ancor Sdn Bhd\",\"isPartOf\":{\"@id\":\"https:\/\/ancor.biz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg\",\"datePublished\":\"2024-10-10T06:40:58+00:00\",\"dateModified\":\"2025-01-23T02:32:57+00:00\",\"description\":\"MEDC PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres\",\"breadcrumb\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#primaryimage\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg\",\"width\":500,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ancor.biz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/ancor.biz\/index.php\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MEDC PH1 Pull Handle Call Point Range\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ancor.biz\/#website\",\"url\":\"https:\/\/ancor.biz\/\",\"name\":\"Ancor Sdn Bhd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/ancor.biz\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ancor.biz\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ancor.biz\/#organization\",\"name\":\"Ancor Sdn Bhd\",\"url\":\"https:\/\/ancor.biz\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"width\":600,\"height\":65,\"caption\":\"Ancor Sdn Bhd\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MEDC PH1 Pull Handle Call Point Range - Ancor Sdn Bhd","description":"MEDC PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/","og_locale":"en_US","og_type":"article","og_title":"MEDC PH1 Pull Handle Call Point Range - Ancor Sdn Bhd","og_description":"MEDC PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres","og_url":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/","og_site_name":"Ancor Sdn Bhd","article_modified_time":"2025-01-23T02:32:57+00:00","og_image":[{"width":500,"height":500,"url":"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/","url":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/","name":"MEDC PH1 Pull Handle Call Point Range - Ancor Sdn Bhd","isPartOf":{"@id":"https:\/\/ancor.biz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#primaryimage"},"image":{"@id":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#primaryimage"},"thumbnailUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg","datePublished":"2024-10-10T06:40:58+00:00","dateModified":"2025-01-23T02:32:57+00:00","description":"MEDC PH1 Pull Handle Call Point Range is designed for use in potentially explosive atmospheres","breadcrumb":{"@id":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#primaryimage","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2024\/10\/MEDC-PH1-Pull-Handle-Call-Point-Range.jpg","width":500,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/ancor.biz\/index.php\/product\/medc-ph1-pull-handle-call-point-range\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ancor.biz\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/ancor.biz\/index.php\/shop\/"},{"@type":"ListItem","position":3,"name":"MEDC PH1 Pull Handle Call Point Range"}]},{"@type":"WebSite","@id":"https:\/\/ancor.biz\/#website","url":"https:\/\/ancor.biz\/","name":"Ancor Sdn Bhd","description":"","publisher":{"@id":"https:\/\/ancor.biz\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ancor.biz\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ancor.biz\/#organization","name":"Ancor Sdn Bhd","url":"https:\/\/ancor.biz\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","width":600,"height":65,"caption":"Ancor Sdn Bhd"},"image":{"@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/51368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/51368\/revisions"}],"predecessor-version":[{"id":51371,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/51368\/revisions\/51371"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media\/51370"}],"wp:attachment":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media?parent=51368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}