{"id":1941,"date":"2021-06-25T04:52:31","date_gmt":"2021-06-24T20:52:31","guid":{"rendered":"https:\/\/ancor.biz\/?post_type=product&#038;p=1941"},"modified":"2025-08-18T15:04:37","modified_gmt":"2025-08-18T07:04:37","slug":"aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500","status":"publish","type":"product","link":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/","title":{"rendered":"AII GPR-2500 Percent Oxygen Analyzer"},"content":{"rendered":"<h1 class=\"product-title\">Percent Oxygen Analyzer in NEMA Enclosure &#8211; AII GPR-2500<\/h1>\n<h2 class=\"product-sub\">For General Purpose and Hazardous Areas<\/h2>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/ancor.biz\/index.php\/product-category\/brand\/analytical-industries-inc-brand\/\">AII<\/a> <a href=\"https:\/\/www.processsensing.com\/en-us\/products\/wall-mounted-percent-oxygen-analyzer.htm?id=wall-mounted-oxygen-analyzer\">GPR-2500<\/a> Percent Oxygen Analyzer is for percentage oxygen measurements in both general purpose or hazardous areas. Available in several variants, all of which are supplied in a lightweight NEMA enclosure with stainless steel wetted parts and easy to access electrochemical oxygen sensors for user-friendly maintenance. Simple to use, and providing best-in-class reliability in demanding industrial environments, our oxygen analyzers are available as fixed installation or as portable instruments for spot-checking processes.<\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"mb-0\">Features:<\/h3>\n<ul class=\"a\">\n<li>Advanced galvanic electrochemical sensors<\/li>\n<li>Measuring oxygen in ranges: 0-1% up to 0-100% (model dependant)<\/li>\n<li>Auto-ranging or fixed range (user selectable)<\/li>\n<li>Long lifespan of the GPR sensor of 32 months and more<\/li>\n<li>Simple to use HMI<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Model &amp; range:<\/h3>\n<table border=\"0\" width=\"626\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td width=\"96\"><\/td>\n<td width=\"131\"><b>GPR-2500N (ATEX)<\/b><\/td>\n<td width=\"129\"><b>GPR-2500A<\/b><\/td>\n<td width=\"125\"><b>GPR-2500MON<\/b><\/td>\n<td width=\"125\"><b>GPR-2500AMO<\/b><\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Measurement range<\/td>\n<td width=\"131\">0-1%, 0-5%, 0-10%, 0-25%<\/td>\n<td width=\"129\">0-1%, 0-5%, 0-10%, 0-25%<\/td>\n<td width=\"125\">0-100%<\/td>\n<td width=\"125\">0-100%<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Accuracy<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">&lt; 2% of range at constant conditions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Response time<\/td>\n<td width=\"131\">T90 &lt; 10 seconds<\/td>\n<td width=\"129\"><\/td>\n<td width=\"125\">T90 &lt; 13 seconds<\/td>\n<td width=\"125\"><\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Sensitivity (LDL)<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">&lt; 0.5% of scale<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Linearity<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">&lt;1% of scale<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Sensor model<\/td>\n<td width=\"131\">GPR-11-32-4<br \/>\nXLT-11-24-4 for gases containing &gt; 0.5% CO2<\/td>\n<td width=\"129\"><\/td>\n<td width=\"125\">GPR-11-120-4<\/td>\n<td width=\"125\"><\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Sensor life in air at 25\u00b0C (77\u00b0F) and 1 atm<\/td>\n<td width=\"131\">GPR-11-32-4: 32 months<br \/>\nXLT-11-24-4: 24 months<\/td>\n<td width=\"129\"><\/td>\n<td width=\"125\">GPR-11-120-4: 24 months in 100% O2<\/td>\n<td width=\"125\"><\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Calibration interval<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">30 days<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Inlet pressure<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">0.34-2 barg (5-30 psig) with atmospheric vent<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Flow rate<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">0.5-1.0 l\/m (1-2 SCFH)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Gas connections<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">1\/8&#8243; compression tube fittings<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Wetted parts<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">Stainless steel<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Display<\/td>\n<td width=\"131\">Graphical LCD 7 x 3.5cm (2.75 x 1.375\u201d); resolution 0.001%<\/td>\n<td width=\"129\"><\/td>\n<td width=\"125\"><\/td>\n<td width=\"125\"><\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Enclosure<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">Fiberglass NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3&#8243;)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Weight<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">3.6kg (8lbs)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Compensation<\/td>\n<td width=\"131\">Temperature<\/td>\n<td width=\"129\">Barometric pressure and temperature<\/td>\n<td width=\"125\">Temperature<\/td>\n<td width=\"125\">Barometric pressure and temperature<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Signal output<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">4-20 mA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Alarms<\/td>\n<td width=\"131\">N\/A<\/td>\n<td width=\"129\">Two user configurable alarms: magnetic coil relays rated 3A at 100 V AC<\/td>\n<td width=\"125\">N\/A<\/td>\n<td width=\"125\">Two user configurable alarms: magnetic coil relays rated 3A at 100 V AC<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Operating temperature<\/td>\n<td colspan=\"4\" width=\"522\">\n<p align=\"CENTER\">GPR sensor: 5\u00b0C to 45\u00b0C (41\u00b0F to 113\u00b0F)<br \/>\nXLT sensor: -10\u00b0 to 45\u00b0C (14\u00b0F to 113\u00b0F)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Power<\/td>\n<td width=\"131\">18-24 V DC<\/td>\n<td width=\"129\">12-28V DC non-loop or 110-220 V AC<\/td>\n<td width=\"125\">18-24 V DC<\/td>\n<td width=\"125\">12-28 V DC non-loop or 110-220 V AC<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Area Classification<\/td>\n<td width=\"131\">II 2 G<br \/>\nEx ia IIB T4 Gb<br \/>\nT<sub>amb<\/sub>\u00a0-20\u00b0C to +50\u00b0C<\/td>\n<td width=\"129\"><\/td>\n<td width=\"125\"><\/td>\n<td width=\"125\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Percent Oxygen Analyzer in NEMA Enclosure &#8211; AII GPR-2500 For General Purpose and Hazardous Areas &nbsp; AII GPR-2500 Percent Oxygen Analyzer is for percentage oxygen measurements in both general purpose or hazardous areas. Available in several variants, all of which are supplied in a lightweight NEMA enclosure with stainless steel wetted parts and easy to &#8230; <a title=\"AII GPR-2500 Percent Oxygen Analyzer\" class=\"read-more\" href=\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/\" aria-label=\"More on AII GPR-2500 Percent Oxygen Analyzer\">Read more<\/a><\/p>\n","protected":false},"featured_media":1942,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"spay_email":""},"class_list":["post-1941","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-analytical-industries-inc-dwyer-omega","product_cat-analytical-industries-inc-brand","product_cat-brand","product_cat-dwyer-omega","product_cat-gas-analyzer-analytical-industries-inc-dwyer-omega","product_cat-gas-analyzer","product_cat-industrial-gas-gas-analyzer","product_cat-gas-analyser","product_cat-analytical-industries-inc","product_cat-industrial-gas","product_tag-aii-gpr-2500","product_tag-aii-gpr-2500-percent-oxygen-analyzer","product_tag-aii-oxygen-gas-analyser","product_tag-gpr-2500-a","product_tag-gpr-2500-amo","product_tag-gpr-2500-mon","product_tag-gpr-2500-n-atex","product_tag-gpr-2500-percent-oxygen-analyzer","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","do-quantity-buttons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>AII GPR-2500 Percent Oxygen Analyzer - Ancor Sdn Bhd<\/title>\n<meta name=\"description\" content=\"AII GPR-2500 Percent Oxygen Analyzer is an industrial oxygen analyzer for percentage oxygen measurements in both general or hazardous areas.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AII GPR-2500 Percent Oxygen Analyzer - Ancor Sdn Bhd\" \/>\n<meta property=\"og:description\" content=\"AII GPR-2500 Percent Oxygen Analyzer is an industrial oxygen analyzer for percentage oxygen measurements in both general or hazardous areas.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/\" \/>\n<meta property=\"og:site_name\" content=\"Ancor Sdn Bhd\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-18T07:04:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/\",\"url\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/\",\"name\":\"AII GPR-2500 Percent Oxygen Analyzer - Ancor Sdn Bhd\",\"isPartOf\":{\"@id\":\"https:\/\/ancor.biz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png\",\"datePublished\":\"2021-06-24T20:52:31+00:00\",\"dateModified\":\"2025-08-18T07:04:37+00:00\",\"description\":\"AII GPR-2500 Percent Oxygen Analyzer is an industrial oxygen analyzer for percentage oxygen measurements in both general or hazardous areas.\",\"breadcrumb\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#primaryimage\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png\",\"width\":300,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ancor.biz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/ancor.biz\/index.php\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"AII GPR-2500 Percent Oxygen Analyzer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ancor.biz\/#website\",\"url\":\"https:\/\/ancor.biz\/\",\"name\":\"Ancor Sdn Bhd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/ancor.biz\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ancor.biz\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ancor.biz\/#organization\",\"name\":\"Ancor Sdn Bhd\",\"url\":\"https:\/\/ancor.biz\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"width\":600,\"height\":65,\"caption\":\"Ancor Sdn Bhd\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AII GPR-2500 Percent Oxygen Analyzer - Ancor Sdn Bhd","description":"AII GPR-2500 Percent Oxygen Analyzer is an industrial oxygen analyzer for percentage oxygen measurements in both general or hazardous areas.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/","og_locale":"en_US","og_type":"article","og_title":"AII GPR-2500 Percent Oxygen Analyzer - Ancor Sdn Bhd","og_description":"AII GPR-2500 Percent Oxygen Analyzer is an industrial oxygen analyzer for percentage oxygen measurements in both general or hazardous areas.","og_url":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/","og_site_name":"Ancor Sdn Bhd","article_modified_time":"2025-08-18T07:04:37+00:00","og_image":[{"width":300,"height":300,"url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/","url":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/","name":"AII GPR-2500 Percent Oxygen Analyzer - Ancor Sdn Bhd","isPartOf":{"@id":"https:\/\/ancor.biz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#primaryimage"},"image":{"@id":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#primaryimage"},"thumbnailUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png","datePublished":"2021-06-24T20:52:31+00:00","dateModified":"2025-08-18T07:04:37+00:00","description":"AII GPR-2500 Percent Oxygen Analyzer is an industrial oxygen analyzer for percentage oxygen measurements in both general or hazardous areas.","breadcrumb":{"@id":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#primaryimage","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aiianalytical-GPR-2500Seriesoxygenanalyser-1.png","width":300,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/ancor.biz\/index.php\/product\/aii-percent-oxygen-analyzer-in-nema-enclosure-aii-gpr-2500\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ancor.biz\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/ancor.biz\/index.php\/shop\/"},{"@type":"ListItem","position":3,"name":"AII GPR-2500 Percent Oxygen Analyzer"}]},{"@type":"WebSite","@id":"https:\/\/ancor.biz\/#website","url":"https:\/\/ancor.biz\/","name":"Ancor Sdn Bhd","description":"","publisher":{"@id":"https:\/\/ancor.biz\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ancor.biz\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ancor.biz\/#organization","name":"Ancor Sdn Bhd","url":"https:\/\/ancor.biz\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","width":600,"height":65,"caption":"Ancor Sdn Bhd"},"image":{"@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/1941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":9,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/1941\/revisions"}],"predecessor-version":[{"id":52376,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/1941\/revisions\/52376"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media\/1942"}],"wp:attachment":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media?parent=1941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}