{"id":1915,"date":"2021-06-25T03:23:07","date_gmt":"2021-06-25T03:23:07","guid":{"rendered":"https:\/\/ancor.biz\/?post_type=product&#038;p=1915"},"modified":"2025-08-18T15:04:40","modified_gmt":"2025-08-18T07:04:40","slug":"aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2","status":"publish","type":"product","link":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/","title":{"rendered":"AII 3000 Series Palm O2 Nitrox Analysers"},"content":{"rendered":"<div class=\"page-header\">\n<h1 class=\"blue\">Nitrox Analysers for Welding AII-3000 Series, Palm O2<\/h1>\n<p>&nbsp;<\/p>\n<\/div>\n<div>AII <a href=\"https:\/\/aii1.com\/industrial_gas_purity\/\">3000 Series<\/a> Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases. <a href=\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\">AII 3000<\/a> Series Palm O2 Nitrox Analysers monitors use similar electrochemical galvanic fuel cell oxygen sensor. It used to measure concentrations from 0% to 100% O2 in gas streams.<\/div>\n<p>&nbsp;<\/p>\n<h3>Features :<\/h3>\n<div>\n<ul>\n<li>0-100% O<sub>2<\/sub> measurement range<\/li>\n<li>Long sensor life up to 60 months (AII-3000)<\/li>\n<li>Battery life up to 13,000 hours of continuous use (Palm O<sub>2<\/sub>)<\/li>\n<li>Integrated or remote sensors<\/li>\n<li>Fast response time of T90 in &lt;10 seconds<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<h3>Model<\/h3>\n<table class=\"table-hover tech-specs\" border=\"1\">\n<thead>\n<tr>\n<th width=\"20%\"><\/th>\n<th width=\"26%\">AII-3000<\/th>\n<th width=\"26%\">Palm O<sub>2<\/sub><\/th>\n<th width=\"26%\">Palm CO Analyzer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Measurement range<\/td>\n<td colspan=\"2\">0-100% oxygen<\/td>\n<td>0-25 ppm CO<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td colspan=\"2\">&lt; \u00b12% of FS range under constant conditions<\/td>\n<td>&lt; \u00b12 ppm under constant conditions<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td colspan=\"2\">T90 &lt; 10 seconds<\/td>\n<td>T90 &lt; 30 seconds<\/td>\n<\/tr>\n<tr>\n<td>Sensitivity (LDL)<\/td>\n<td colspan=\"2\">0.50%<\/td>\n<td>0.5 ppm CO<\/td>\n<\/tr>\n<tr>\n<td>Linearity<\/td>\n<td colspan=\"3\">\u00b11% under constant conditions<\/td>\n<\/tr>\n<tr>\n<td>Sensor model<\/td>\n<td>AII-11-60 (remote sensor)<br \/>\nAII-11-60-HC<\/td>\n<td>AII-11-75-PO2<br \/>\nAII-11-75-PO2-D (for diving)<\/td>\n<td>OSV-22-AF<\/td>\n<\/tr>\n<tr>\n<td>Sensor life at 25\u00b0C (77\u00b0F) and 1 atmosphere<\/td>\n<td>60 months in air 5\u00b0C (77\u00b0F) and 1 atmosphere<\/td>\n<td>32 months in air 5\u00b0C (77\u00b0F) and 1 atmosphere<\/td>\n<td>24 months in air 5\u00b0C (77\u00b0F) at 1 atmosphere<\/td>\n<\/tr>\n<tr>\n<td>Calibration interval<\/td>\n<td colspan=\"2\">Prior to use and after 8 hours operation<\/td>\n<td>Certified span gas mixture of CO concentrations between 10-20 ppm with balance air.<\/td>\n<\/tr>\n<tr>\n<td>Inlet pressure<\/td>\n<td colspan=\"2\">Ambient or 0.34-2 barg (5-30 psig) for flow through connector<\/td>\n<td>800 1200 mbara (11.6-17.4 psig)<\/td>\n<\/tr>\n<tr>\n<td>Flow rate (constant)<\/td>\n<td colspan=\"3\">0.2-10 Nl\/min (0.4-20 SCFH)<\/td>\n<\/tr>\n<tr>\n<td>Gas connections<\/td>\n<td colspan=\"2\">1&#215;16 mm thread<br \/>\n1\/4&#8243; tube for remote sensors<br \/>\nSee accessories for additional connectors<\/td>\n<td>Supplied with Dome adapter (A-3388) with optional BC adapter (A-3671)<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>3\u00bd digit backlit LCD 7 x 3.5cm (2.75 x 1.375&#8243;); resolution 0.1<\/td>\n<td>3 digit LCD 2.8 x 1.6cm (1.1 x 0.625&#8243;); resolution 0.1<\/td>\n<td>2 digit LCD 2.8 x 1.6cm (1.1 x 0.625&#8243;); resolution 1 ppm CO<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>9.1 x 14.9 x 4cm (3.6 x 5.9 x 1.6&#8243;)<\/td>\n<td colspan=\"2\">6.9 x 10.4 x 3.4cm (2.72&#8243; x 4.1&#8243; x 1.35&#8243;)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>280g (10oz)<\/td>\n<td colspan=\"2\">196g (7oz)<\/td>\n<\/tr>\n<tr>\n<td>Compensation<\/td>\n<td colspan=\"2\">Temperature compensated<\/td>\n<td>NA<\/td>\n<\/tr>\n<tr>\n<td>Alarms<\/td>\n<td colspan=\"3\">User adjustable HI and LO alarms (AII-3000 M and MHC only)<\/td>\n<\/tr>\n<tr>\n<td>Storage temperature<\/td>\n<td colspan=\"2\">-20\u00b0C to +60\u00b0C (-4\u00b0F to 140\u00b0F) on intermittent basis<\/td>\n<td>3\u00b0C to 35\u00b0C (37.4\u00b0F to 95\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td colspan=\"2\">5 to 45\u00b0C (41\u00b0F to 113\u00b0F)<\/td>\n<td>0\u00b0C to 50\u00b0C (32\u00b0F to 122\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td colspan=\"3\">2 AA alkaline batteries<\/td>\n<\/tr>\n<tr>\n<td>Battery Life<\/td>\n<td>Up to 1200 hrs<\/td>\n<td>Up to 1300 hrs<\/td>\n<td>Up to 450 hrs of continual use<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td colspan=\"3\">Non-condensing 0-95% RH<\/td>\n<\/tr>\n<tr>\n<td>Warm up time<\/td>\n<td colspan=\"2\">None<\/td>\n<td>60 Seconds<\/td>\n<\/tr>\n<tr>\n<td>Approvals<\/td>\n<td>ISO 9001:2000, MDD 93\/42\/Annex II, ISO 13485:2003<\/td>\n<td colspan=\"2\">None<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Nitrox Analysers for Welding AII-3000 Series, Palm O2 &nbsp; AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases. AII 3000 Series Palm O2 Nitrox Analysers monitors use similar electrochemical galvanic fuel cell oxygen sensor. It used to measure concentrations from 0% to 100% O2 in gas &#8230; <a title=\"AII 3000 Series Palm O2 Nitrox Analysers\" class=\"read-more\" href=\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\" aria-label=\"More on AII 3000 Series Palm O2 Nitrox Analysers\">Read more<\/a><\/p>\n","protected":false},"featured_media":1903,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"spay_email":""},"class_list":["post-1915","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-analytical-industries-inc-dwyer-omega","product_cat-analytical-industries-inc-brand","product_cat-brand","product_cat-dwyer-omega","product_cat-gas-analyzer-analytical-industries-inc-dwyer-omega","product_cat-gas-analyzer","product_cat-industrial-gas-gas-analyzer","product_cat-gas-analyser","product_cat-analytical-industries-inc","product_cat-industrial-gas","product_tag-aii-3000-series-palm-o2","product_tag-aii-3000-series-palm-o2-nitrox-analysers","product_tag-aii-3000-series","product_tag-palm-co-analyzer","product_tag-palm-o2","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","do-quantity-buttons","wc-has-gallery"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>AII 3000 Series Palm O2 Nitrox Analysers - Ancor Sdn Bhd<\/title>\n<meta name=\"description\" content=\"AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AII 3000 Series Palm O2 Nitrox Analysers - Ancor Sdn Bhd\" \/>\n<meta property=\"og:description\" content=\"AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\" \/>\n<meta property=\"og:site_name\" content=\"Ancor Sdn Bhd\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-18T07:04:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\",\"url\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\",\"name\":\"AII 3000 Series Palm O2 Nitrox Analysers - Ancor Sdn Bhd\",\"isPartOf\":{\"@id\":\"https:\/\/ancor.biz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png\",\"datePublished\":\"2021-06-25T03:23:07+00:00\",\"dateModified\":\"2025-08-18T07:04:40+00:00\",\"description\":\"AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases\",\"breadcrumb\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#primaryimage\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png\",\"width\":350,\"height\":350},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ancor.biz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/ancor.biz\/index.php\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"AII 3000 Series Palm O2 Nitrox Analysers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ancor.biz\/#website\",\"url\":\"https:\/\/ancor.biz\/\",\"name\":\"Ancor Sdn Bhd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/ancor.biz\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ancor.biz\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ancor.biz\/#organization\",\"name\":\"Ancor Sdn Bhd\",\"url\":\"https:\/\/ancor.biz\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"width\":600,\"height\":65,\"caption\":\"Ancor Sdn Bhd\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AII 3000 Series Palm O2 Nitrox Analysers - Ancor Sdn Bhd","description":"AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/","og_locale":"en_US","og_type":"article","og_title":"AII 3000 Series Palm O2 Nitrox Analysers - Ancor Sdn Bhd","og_description":"AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases","og_url":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/","og_site_name":"Ancor Sdn Bhd","article_modified_time":"2025-08-18T07:04:40+00:00","og_image":[{"width":350,"height":350,"url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/","url":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/","name":"AII 3000 Series Palm O2 Nitrox Analysers - Ancor Sdn Bhd","isPartOf":{"@id":"https:\/\/ancor.biz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#primaryimage"},"image":{"@id":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#primaryimage"},"thumbnailUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png","datePublished":"2021-06-25T03:23:07+00:00","dateModified":"2025-08-18T07:04:40+00:00","description":"AII 3000 Series Palm O2 Nitrox Analysers are a convenient way to check oxygen levels in welding gases","breadcrumb":{"@id":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#primaryimage","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/06\/aii-Handheld-O2-Monitors-AII-3000-and-Palm-O2.png","width":350,"height":350},{"@type":"BreadcrumbList","@id":"https:\/\/ancor.biz\/index.php\/product\/aii-nitrox-analysers-for-welding-aii-3000-series-palm-o2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ancor.biz\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/ancor.biz\/index.php\/shop\/"},{"@type":"ListItem","position":3,"name":"AII 3000 Series Palm O2 Nitrox Analysers"}]},{"@type":"WebSite","@id":"https:\/\/ancor.biz\/#website","url":"https:\/\/ancor.biz\/","name":"Ancor Sdn Bhd","description":"","publisher":{"@id":"https:\/\/ancor.biz\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ancor.biz\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ancor.biz\/#organization","name":"Ancor Sdn Bhd","url":"https:\/\/ancor.biz\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","width":600,"height":65,"caption":"Ancor Sdn Bhd"},"image":{"@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/1915","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":6,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/1915\/revisions"}],"predecessor-version":[{"id":52383,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/1915\/revisions\/52383"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media\/1903"}],"wp:attachment":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media?parent=1915"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}