{"id":11102,"date":"2022-09-28T04:55:35","date_gmt":"2022-09-27T20:55:35","guid":{"rendered":"https:\/\/ancor.biz\/?post_type=product&#038;p=11102"},"modified":"2024-10-28T12:53:41","modified_gmt":"2024-10-28T04:53:41","slug":"barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f","status":"publish","type":"product","link":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/","title":{"rendered":"BARKSDALE ML1H Temperature Switch -50F-75F"},"content":{"rendered":"<h1 class=\"sub-title1\">Description<\/h1>\n<p>&nbsp;<\/p>\n<div class=\"ProductDescriptionContainer\">\n<p><a href=\"https:\/\/ancor.biz\/index.php\/product-category\/brand\/barksdale-inc\/\">BARKSDALE<\/a> ML1H Temperature Switch -50F-75F, ML1H &amp; L2H Series Temperature Switches provide unmatched performance, quality &amp; reliability in a mechanical thermostat. The single set point ML1H and dual set point L2H, can switch, measure &amp; control temperatures from -50\u00b0 to 450\u00b0F (-45\u00b0 to 232\u00b0C), while the optional adjustable differential provides precise control.<\/p>\n<p>BARKSDALE ML1H Temperature Switch -50F-75F these locally mounted switches provide fast response and accurate measurements at the temperature source. Both the ML1H &amp; L2H Series are electrically rated for 10 amps @ 125\/250 VAC &amp; 3 amps @ 480 VAC. Standard 3- &amp; 6-pin terminal strips simplify installation.<\/p>\n<p>The ML1H &amp; L2H Series are rated NEMA 4 &amp; 13; the optional NEMA 4X construction protects the rugged die-cast aluminum enclosure from corrosive environments. Copper or stainless steel temperature sensors are available to handle a wide range of media. Optional thermowells allow the sensor to work in pressurized vessels to 5000 psi. UL listed &amp; CSA approved, ML1H &amp; L2H Series Temperature Switches are perfect for your temperature sensing needs.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"ProductDescriptionContainer\">\n<p><strong>Features:<\/strong><\/p>\n<ul>\n<li>Reliable &amp; accurate<\/li>\n<li>Local sensing<\/li>\n<li>NEMA 4<\/li>\n<li>UL, CSA &amp; CE approved<\/li>\n<li>Single or dual switching<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Applications:<\/strong><\/p>\n<ul>\n<li>Oil &amp; gas<\/li>\n<li>Mining<\/li>\n<li>Tanks and reservoirs<\/li>\n<li>Compressors<\/li>\n<li>Plastic machinery<\/li>\n<li>Factory automation<\/li>\n<li>Process equipment<\/li>\n<li>Machine tools and industrial equipment<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>Model<\/strong><\/p>\n<div align=\"RIGHT\">\n<table border=\"1\" width=\"641\" cellspacing=\"0\" cellpadding=\"4\">\n<tbody>\n<tr valign=\"TOP\">\n<td width=\"55\"><b>Model<\/b><\/td>\n<td width=\"56\"><b>Accuracy<\/b><\/td>\n<td width=\"56\"><b>Electrical Connection<\/b><\/td>\n<td width=\"56\"><b>Low Range<\/b><\/td>\n<td width=\"56\"><b>High<\/b><\/p>\n<p><b>Range<\/b><\/td>\n<td width=\"56\"><b>Type <\/b><\/td>\n<td width=\"56\"><b>Rating <\/b><\/td>\n<td width=\"56\"><b>Wetted Material <\/b><\/td>\n<td width=\"56\"><b>Enclosure <\/b><\/td>\n<td width=\"55\"><b>Option<\/b><\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-B201<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250\/480 VAC; 2 amps @ 600 VAC; 0.05 amps @ 125 VDC; 0.03 amps @ 250 VDC<\/td>\n<td width=\"56\">Brass<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\"><\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-B201S-WS<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250\/480 VAC; 2 amps @ 600 VAC; 0.05 amps @ 125 VDC; 0.03 amps @ 250 VDC<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">316 stainless steel local mount thermowell<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-G201-W-RD<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250\/480 VAC; 2 amps @ 600 VAC; 0.4 amps @ 125 VDC; MANUAL RESET<\/td>\n<td width=\"56\">Brass<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">Brass local mount thermowell<\/p>\n<p>Manual Reset<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-G201S-RD<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250\/480 VAC; 2 amps @ 600 VAC; 0.4 amps @ 125 VDC; MANUAL RESET<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">Manual Reset<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-G201S-WS-RD<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250\/480 VAC; 2 amps @ 600 VAC; 0.4 amps @ 125 VDC; MANUAL RESET<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">316 stainless steel local mount thermowell<\/p>\n<p>Manual Reset<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-H201<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250 VAC; 3 amp @ 480 VAC<\/td>\n<td width=\"56\">Brass<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\"><\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-H201-W<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250 VAC; 3 amp @ 480 VAC<\/td>\n<td width=\"56\">Brass<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">Brass local mount thermowell<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-H201-WS<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250 VAC; 3 amp @ 480 VAC<\/td>\n<td width=\"56\">Brass<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">316 stainless steel local mount thermowell<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-H201S<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250 VAC; 3 amp @ 480 VAC<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\"><\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-H201S-WS<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250 VAC; 3 amp @ 480 VAC<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">316 stainless steel local mount thermowell<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-L201-W<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">15 amps @ 125\/250\/480 VAC; 0.03 amps @ 125 VDC; 0.02 amps @ 250 VDC<\/td>\n<td width=\"56\">Brass<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">Brass local mount thermowell<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-L201S-WS<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">15 amps @ 125\/250\/480 VAC; 0.03 amps @ 125 VDC; 0.02 amps @ 250 VDC<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">316 stainless steel local mount thermowell<\/td>\n<\/tr>\n<tr valign=\"TOP\">\n<td width=\"55\">ML1H-M201S-WS<\/td>\n<td width=\"56\">\u00b11% of mid-60% of full range. At constant ambient \u00b1 0.5% of full scale<\/td>\n<td width=\"56\">3-pin terminal strip<\/td>\n<td width=\"56\">-50\u00b0 F<\/td>\n<td width=\"56\">+75\u00b0 F<\/td>\n<td width=\"56\">Single switch, Single set point (SPDT)<\/td>\n<td width=\"56\">10 amps @ 125\/250 VAC; 3 amp @ 480 VAC; 0.5 amps @ 125 VDC; 0.25 amps @ 250 VDC<\/td>\n<td width=\"56\">304 stainless steel sensor<\/td>\n<td width=\"56\">NEMA 4 enclosure<\/td>\n<td width=\"55\">316 stainless steel local mount thermowell<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Description &nbsp; BARKSDALE ML1H Temperature Switch -50F-75F, ML1H &amp; L2H Series Temperature Switches provide unmatched performance, quality &amp; reliability in a mechanical thermostat. The single set point ML1H and dual set point L2H, can switch, measure &amp; control temperatures from -50\u00b0 to 450\u00b0F (-45\u00b0 to 232\u00b0C), while the optional adjustable differential provides precise control. BARKSDALE &#8230; <a title=\"BARKSDALE ML1H Temperature Switch -50F-75F\" class=\"read-more\" href=\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/\" aria-label=\"More on BARKSDALE ML1H Temperature Switch -50F-75F\">Read more<\/a><\/p>\n","protected":false},"featured_media":11103,"template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"spay_email":""},"class_list":["post-11102","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-barksdale-temperature-switch","product_cat-local-mount","product_cat-switch","product_cat-temperature-switch","product_tag-barksdale-ml1h-temperature-switch","product_tag-ml1h-b201","product_tag-ml1h-b201s-ws","product_tag-ml1h-g201-w-rd","product_tag-ml1h-g201s-rd","product_tag-ml1h-g201s-ws-rd","product_tag-ml1h-h201","product_tag-ml1h-h201-w","product_tag-ml1h-h201-ws","product_tag-ml1h-h201s","product_tag-ml1h-h201s-ws","product_tag-ml1h-l201-w","product_tag-ml1h-l201s-ws","product_tag-ml1h-m201s-ws","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","do-quantity-buttons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>BARKSDALE ML1H Temperature Switch -50F-75F - Ancor Sdn Bhd<\/title>\n<meta name=\"description\" content=\"BARKSDALE ML1H Temperature Switch -50F-75F, ML1H &amp; L2H Series ML1H-B201, ML1H-B201S-WS, ML1H-G201-W-RD, ML1H-G201S-RD, ML1H-G201S-WS-RD, ML1H-H201, ML1H-H201-W, ML1H-H201-WS, ML1H-H201S, ML1H-H201S-WS, ML1H-L201-W, ML1H-L201S-WS, ML1H-M201S-WS\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"BARKSDALE ML1H Temperature Switch -50F-75F - Ancor Sdn Bhd\" \/>\n<meta property=\"og:description\" content=\"BARKSDALE ML1H Temperature Switch -50F-75F, ML1H &amp; L2H Series ML1H-B201, ML1H-B201S-WS, ML1H-G201-W-RD, ML1H-G201S-RD, ML1H-G201S-WS-RD, ML1H-H201, ML1H-H201-W, ML1H-H201-WS, ML1H-H201S, ML1H-H201S-WS, ML1H-L201-W, ML1H-L201S-WS, ML1H-M201S-WS\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/\" \/>\n<meta property=\"og:site_name\" content=\"Ancor Sdn Bhd\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-28T04:53:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/\",\"url\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/\",\"name\":\"BARKSDALE ML1H Temperature Switch -50F-75F - Ancor Sdn Bhd\",\"isPartOf\":{\"@id\":\"https:\/\/ancor.biz\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png\",\"datePublished\":\"2022-09-27T20:55:35+00:00\",\"dateModified\":\"2024-10-28T04:53:41+00:00\",\"description\":\"BARKSDALE ML1H Temperature Switch -50F-75F, ML1H & L2H Series ML1H-B201, ML1H-B201S-WS, ML1H-G201-W-RD, ML1H-G201S-RD, ML1H-G201S-WS-RD, ML1H-H201, ML1H-H201-W, ML1H-H201-WS, ML1H-H201S, ML1H-H201S-WS, ML1H-L201-W, ML1H-L201S-WS, ML1H-M201S-WS\",\"breadcrumb\":{\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#primaryimage\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png\",\"width\":900,\"height\":900},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/ancor.biz\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/ancor.biz\/index.php\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"BARKSDALE ML1H Temperature Switch -50F-75F\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/ancor.biz\/#website\",\"url\":\"https:\/\/ancor.biz\/\",\"name\":\"Ancor Sdn Bhd\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/ancor.biz\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/ancor.biz\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/ancor.biz\/#organization\",\"name\":\"Ancor Sdn Bhd\",\"url\":\"https:\/\/ancor.biz\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"contentUrl\":\"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png\",\"width\":600,\"height\":65,\"caption\":\"Ancor Sdn Bhd\"},\"image\":{\"@id\":\"https:\/\/ancor.biz\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"BARKSDALE ML1H Temperature Switch -50F-75F - Ancor Sdn Bhd","description":"BARKSDALE ML1H Temperature Switch -50F-75F, ML1H & L2H Series ML1H-B201, ML1H-B201S-WS, ML1H-G201-W-RD, ML1H-G201S-RD, ML1H-G201S-WS-RD, ML1H-H201, ML1H-H201-W, ML1H-H201-WS, ML1H-H201S, ML1H-H201S-WS, ML1H-L201-W, ML1H-L201S-WS, ML1H-M201S-WS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/","og_locale":"en_US","og_type":"article","og_title":"BARKSDALE ML1H Temperature Switch -50F-75F - Ancor Sdn Bhd","og_description":"BARKSDALE ML1H Temperature Switch -50F-75F, ML1H & L2H Series ML1H-B201, ML1H-B201S-WS, ML1H-G201-W-RD, ML1H-G201S-RD, ML1H-G201S-WS-RD, ML1H-H201, ML1H-H201-W, ML1H-H201-WS, ML1H-H201S, ML1H-H201S-WS, ML1H-L201-W, ML1H-L201S-WS, ML1H-M201S-WS","og_url":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/","og_site_name":"Ancor Sdn Bhd","article_modified_time":"2024-10-28T04:53:41+00:00","og_image":[{"width":900,"height":900,"url":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/","url":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/","name":"BARKSDALE ML1H Temperature Switch -50F-75F - Ancor Sdn Bhd","isPartOf":{"@id":"https:\/\/ancor.biz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#primaryimage"},"image":{"@id":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#primaryimage"},"thumbnailUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png","datePublished":"2022-09-27T20:55:35+00:00","dateModified":"2024-10-28T04:53:41+00:00","description":"BARKSDALE ML1H Temperature Switch -50F-75F, ML1H & L2H Series ML1H-B201, ML1H-B201S-WS, ML1H-G201-W-RD, ML1H-G201S-RD, ML1H-G201S-WS-RD, ML1H-H201, ML1H-H201-W, ML1H-H201-WS, ML1H-H201S, ML1H-H201S-WS, ML1H-L201-W, ML1H-L201S-WS, ML1H-M201S-WS","breadcrumb":{"@id":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#primaryimage","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2022\/09\/Barksdale-ML1H-Series-Local-Mount-Temperature-Switch-Single-Setpoint-50-F-to-75-F.png","width":900,"height":900},{"@type":"BreadcrumbList","@id":"https:\/\/ancor.biz\/index.php\/product\/barksdale-ml1h-series-local-mount-temperature-switch-single-setpoint-50-f-to-75-f\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ancor.biz\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/ancor.biz\/index.php\/shop\/"},{"@type":"ListItem","position":3,"name":"BARKSDALE ML1H Temperature Switch -50F-75F"}]},{"@type":"WebSite","@id":"https:\/\/ancor.biz\/#website","url":"https:\/\/ancor.biz\/","name":"Ancor Sdn Bhd","description":"","publisher":{"@id":"https:\/\/ancor.biz\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ancor.biz\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ancor.biz\/#organization","name":"Ancor Sdn Bhd","url":"https:\/\/ancor.biz\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/","url":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","contentUrl":"https:\/\/ancor.biz\/wp-content\/uploads\/2021\/05\/ancor-logo.png","width":600,"height":65,"caption":"Ancor Sdn Bhd"},"image":{"@id":"https:\/\/ancor.biz\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/11102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":6,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/11102\/revisions"}],"predecessor-version":[{"id":50199,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/product\/11102\/revisions\/50199"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media\/11103"}],"wp:attachment":[{"href":"https:\/\/ancor.biz\/index.php\/wp-json\/wp\/v2\/media?parent=11102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}